Separering som tiltak for reduksjon av fremmedvann. Hvor effektivt er det å separere avløpssystemet for å redusere andel fremmedvann?

Habibi, Wasim
Master thesis
Thumbnail
View/Open
no.ntnu:inspera:130637930:29614278.pdf (11.08Mb)
no.ntnu:inspera:130637930:29614278.zip (4.989Mb)
URI
https://hdl.handle.net/11250/3066657
Date
2023
Metadata
Show full item record
Collections
  • Institutt for bygg- og miljøteknikk [4483]
Abstract
Fremmedvann i avløpssystemet er et stort problem for mange kommuner i Norge med

negative konsekvenser som kapasitetssvikt i avløpsledningene, miljømessige konsekvenser

og ikke minst økonomiske konsekvenser. Å lokalisere fremmedvannkilder og tiltak for

reduksjon av fremmedvannsandel i avløpsnettet er ikke en engangsjobb, men kontinuerlig

prosess som krever langtidsplanlegging, vedvarende innsats og moderne teknologi og utstyr.

Det finnes flere typer av tiltak mot reduksjon av fremmedvann i avløpssystemet, men i

denne oppgaven har jeg forsøkt å se på effekten av separering som tiltak mot reduksjon av

fremmedvann. Lørenskog kommune er benyttet som case og delområde masteroppgaven

omhandler er nord for Lørenskog sentrum. Med utgangspunktet i to ulike type delområder

A- Ødegård som har separat avløpssystem og delområde B – Grønlia som har felles

avløpssystem. Areal, befolkningstall og antall km ledningsnett er kriteriene som er lagt til

grunn for valg av prosjektområdene. For å finne fremmedvannsandelen ble det brukt

vannførings-, temperatur- og nedbørsmålinger sammen med avløpsprøver som ble analysert

for både Tot-P og pH. Målinger og prøver ble tatt fra de to kummene som er felles

avrenningspunkt for hver sitt område.

Resultatene viste store fremmedvannmengder, både fra konstant innlekking under tørrvær

og direkte innlekking under nedbørsperioder. For hele delområde A- Ødegård var

fremmedvannsandelen på 38 % fra konstant innlekking og 36% fra direkte innlekking i

nedbørsepisoder. Beregnet innlekking basert på målt vannføring viser konstant innlekking på

1,14 L/s og fra direkte innlekking under nedbørsperioder på 1,64 L/s. For delområde BGrønlia

var fremmedvannsandelen på 63 % fra konstant innlekking og 93,1% fra direkte

innlekking i nedbørsperioder. Beregnet innlekking basert på målt vannføring viser konstant

innlekking på 3,86 L/s og fra direkte innlekking under nedbørsperioder på 17,86 L/s.

Delområde A har separatsystem og ledningsnettet er fra 2015-2021 som er i god stand, men

det kommer en del fremmedvann inn i ledningsnettet. Det viser seg sannsynlig at området

har feilkoblinger (ifølge kommunalteknisk) som bidrar til fremmedvann i systemet. Konstant

innlekking er like mye som nedbørsbetinget innlekking i område. Delområde B har felles

avløpssystem og byggeår varierer fra 1949 – 1994 og er i relativt dårlig stand.

Fremmedvannbidragene i delområde B kommer fra både konstant innlekking og

nedbørsbetinget innlekking. Sist nevnte bidrar mest til andel fremmedvann i område spesielt

i nedbørsperioder. Nedbørpåvirket innlekking fører til hyppigere overløpsepisoder fra

fellesavløpssystemene og som resultat gir den største miljømessige belastningen. Tiltak som

å separere avløpssystem, lokal overvannsdisponering, fjerning av feilkoblinger, tetting av

drikkevannslekkasjer er gode tiltak for å redusere fremmedvannandel i avløpsnettet.
 
Infiltration and inflow (I/I) in the sewage system is a major problem for many municipalities

in Norway with negative consequences such as capacity failure in the sewer lines,

environmental consequences, and not least economic consequences. Locating infiltration

and inflow (I/I) sources and measures to reduce the proportion of it in the sewage system is

not a one-time job, but a continuous process that requires long-term planning, sustained

effort and modern technology and equipment.

There are several types of measures against the reduction of foreign water in the sewage

system, but in this thesis, I have tried to look at the effect of separation as measures against

the reduction of foreign water. Lørenskog municipality is used as a case and sub-area the

master's thesis deals with is north of Lørenskog center. Based on two different types of subareas

A- Ødegård which have a separate sewage system and sub-area B – Grønlia which has

a common sewage system. Area, population figures and number of kilometers of pipe

networks are the criteria used as a basis for choosing the project areas. To find the volume

of infiltration and inflow, water flow, temperature and precipitation measurements were

used together with sewage samples that were analyzed for both Tot-P and pH.

Measurements and samples were taken from the two manholes, which are common runoff

points for separate areas.

The results showed large amounts of foreign water, both from constant leaking during dry

weather and direct leaking during precipitation periods. For the entire sub-area A- Ødegård,

the volume of infiltration and inflow was 38 % from constant leaking and 36 % from direct

leaking in precipitation episodes. Estimated leaking based on measured water flow shows

constant leaking of 1.14 L/s and from direct leaking during precipitation periods of 1.64 L/s.

For sub-area B-Grønlia, the volume of infiltration and inflow was 63 % from constant leaking

and 93.1 % from direct leaking during precipitation periods. Estimated leaking based on

measured water flow shows constant leaking of 3.86 L/s and from direct leaking during

precipitation periods of 17.86 L/s.

Sub-area A has a separate sewage system, and the pipe network is from 2015-2021 that is in

good condition, but some infiltration and inflow enter the pipe network. It turns out likely

that the area has faulty connections (according to municipal technical) that contribute to

infiltration and inflow in the system. Constant leaking is as much as precipitation-related

leaking in areas. Sub-area B has a common sewage system, and the year of construction

varies from 1949 – 1994 and is in relatively poor condition. The infiltration and inflow

contributions in sub-area B come from both constant leaking and precipitation-related

leaking. The last mentioned contributes most to the proportion of infiltration and inflow in

the area, especially during precipitation periods. Precipitation-affected leaking leads to more

frequent overflow episodes from the common drainage systems and as a result it leads to

the environmental impact. Separating sewage systems, local stormwater disposal, removal

of faulty connections, sealing of drinking water leaks are good measures to reduce the

proportion of infiltration and inflow to the sewage network.
 
Publisher
NTNU

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit
 

 

Browse

ArchiveCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsDocument TypesJournalsThis CollectionBy Issue DateAuthorsTitlesSubjectsDocument TypesJournals

My Account

Login

Statistics

View Usage Statistics

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit