Vis enkel innførsel

dc.contributor.authorLetnes, Jon Magne
dc.contributor.authorEriksen-Volnes, Torfinn
dc.contributor.authorNes, Bjarne
dc.contributor.authorWisløff, Ulrik
dc.contributor.authorSalvesen, Øyvind
dc.contributor.authorDalen, Håvard
dc.date.accessioned2021-11-16T10:09:45Z
dc.date.available2021-11-16T10:09:45Z
dc.date.created2021-11-08T21:54:56Z
dc.date.issued2021
dc.identifier.issn0742-2822
dc.identifier.urihttps://hdl.handle.net/11250/2829795
dc.description.abstractObjective: Investigate variability related to image acquisition and reading process for echocardiographic measures of left ventricular (LV) diastolic function, and its influence on classification of LV diastolic dysfunction (LVDD). Methods: Forty participants (19 women) mean age 62 (28-88) years underwent echocardiographic examinations twice by different echocardiographers and blinded analyses by four readers in a cross-sectional design. Measurements included quantification of two- (2D) and three-dimensional (3D) recordings of the left atrium (LA) (maximal) volume (LAVmax ) and spectral Doppler blood flow and tissue velocities for assessment of LV diastolic function. Variability and reproducibility measures were calculated using variance component analyses and Kappa statistics. Results: Image acquisition influenced variability more than image reading (mean 24% and 4% of variance, respectively), but variability from image reading was especially important for 2D LAVmax (16% of variance) compared to 4% for 3D LAVmax , which was reflected in better agreement for 3D measures. The variability of measures used in classification of LVDD had clinical significance, and agreement across the four raters in classification using current recommendations was only fair (Kappa 0.42), but the agreement improved when using 3D LAVmax (Kappa 0.58). Agreement and reliability measures were reported for all measures. Conclusion: Performing a new image acquisition influenced variability more than a introducing a new image reader, but there were differences across the different measures. LAVmax by 3D is superior to 2D with respect to lower variability. The variability of diastolic measures influences the reliability of LVDD classification, and this should be taken into account in the everyday clinic.en_US
dc.language.isoengen_US
dc.publisherWileyen_US
dc.rightsNavngivelse-Ikkekommersiell 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/deed.no*
dc.titleVariability of echocardiographic measures of left ventricular diastolic function. The HUNT studyen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.source.journalEchocardiographyen_US
dc.identifier.doi10.1111/echo.15073
dc.identifier.cristin1952568
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse-Ikkekommersiell 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse-Ikkekommersiell 4.0 Internasjonal