Show simple item record

dc.contributor.authorHindenes, Lars Bakke
dc.contributor.authorHåberg, Asta
dc.contributor.authorJohnsen, Liv-Hege
dc.contributor.authorMathiesen, Ellisiv B.
dc.contributor.authorDavid, Robben
dc.contributor.authorVangberg, Torgil Riise
dc.date.accessioned2021-02-12T09:33:58Z
dc.date.available2021-02-12T09:33:58Z
dc.date.created2020-12-15T16:12:26Z
dc.date.issued2020
dc.identifier.issn1932-6203
dc.identifier.urihttps://hdl.handle.net/11250/2727630
dc.description.abstractThe main arteries that supply blood to the brain originate from the Circle of Willis (CoW). The CoW exhibits considerable anatomical variations which may have clinical importance, but the variability is insufficiently characterised in the general population. We assessed the anatomical variability of CoW variants in a community-dwelling sample (N = 1,864, 874 men, mean age = 65.4, range 40–87 years), and independent and conditional frequencies of the CoW’s artery segments. CoW segments were classified as present or missing/hypoplastic (w/1mm diameter threshold) on 3T time-of-flight magnetic resonance angiography images. We also examined whether age and sex were associated with CoW variants. We identified 47 unique CoW variants, of which five variants constituted 68.5% of the sample. The complete variant was found in 11.9% of the subjects, and the most common variant (27.8%) was missing both posterior communicating arteries. Conditional frequencies showed patterns of interdependence across most missing segments in the CoW. CoW variants were associated with mean-split age (P = .0147), and there was a trend showing more missing segments with increasing age. We found no association with sex (P = .0526). Our population study demonstrated age as associated with CoW variants, suggesting reduced collateral capacity with older age.en_US
dc.language.isoengen_US
dc.publisherPublic Library of Scienceen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleVariations in the Circle of Willis in a large population sample using 3D TOF angiography: The Tromsø Studyen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.source.journalPLOS ONEen_US
dc.identifier.doi10.1371/journal.pone.0241373
dc.identifier.cristin1860179
dc.relation.projectHelse Nord RHF: SFP1271- 16en_US
dc.relation.projectHelse Nord RHF: HNF1369-17en_US
dc.description.localcode© 2020 Hindenes et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal