dc.contributor.author | Bjærum, Steinar | nb_NO |
dc.date.accessioned | 2014-12-19T13:30:11Z | |
dc.date.available | 2014-12-19T13:30:11Z | |
dc.date.created | 2008-03-28 | nb_NO |
dc.date.issued | 2001 | nb_NO |
dc.identifier | 123887 | nb_NO |
dc.identifier.isbn | 82-7984-163-6 | nb_NO |
dc.identifier.uri | http://hdl.handle.net/11250/249890 | |
dc.language | eng | nb_NO |
dc.publisher | Fakultet for informasjonsteknologi, matematikk og elektroteknikk | nb_NO |
dc.relation.ispartofseries | Dr. ingeniøravhandling, 0809-103X; 2001:2 | nb_NO |
dc.relation.haspart | Bjærum, Steinar; Torp, Hans; Kristoffersen, Kjell. Clutter filters adapted to tissue motion in ultrasound color flow imaging. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. 49(6): 693-704, 2002. | nb_NO |
dc.relation.haspart | Bjærum, Steinar; Torp, Hans. Blood detection performance in moving tissue. Proceedings of the 1998 IEEE Ultrasonics Symposium. 2: 1571-1574, 1998. | nb_NO |
dc.relation.haspart | Bjærum, Steinar; Torp, Hans. Statistical evaluation of clutter filters in color flow imaging. Ultrasonics. 38(5): 376-380, 2000. | nb_NO |
dc.relation.haspart | Bjærum, Steinar; Torp, Hans; Bakke, Torbjørn; Kristoffersen, Kjell. Automatic Selection of the Clutter Filter Cut-off Frequency in Ultrasound Color Flow Imaging. . | nb_NO |
dc.relation.haspart | Bjærum, Steinar; Torp, Hans; Kristoffersen, Kjell; Sætre, Dagfinn. High Frame Rate Color Flow Imaging. . | nb_NO |
dc.relation.haspart | Haugen, Bjørn Olav; Bjærum, Steinar; Samstad, Steinar; Skjærpe, Terje; Torp, Hans. A new method describing cross-sectional blood flow velocity profiles in the left ventricular outflow tract of patients with atrial fibrillation with the use of high- frame rate 2-dimensional color flow imaging. Journal of the American Society of Echocardiography. 14(1): 50-56, 2001. | nb_NO |
dc.relation.haspart | Bjærum, Steinar; Torp, Hans. Blood Motion Imaging . . | nb_NO |
dc.relation.haspart | Bjærum, Steinar; Heimdal, Andreas; Torp, Hans; Amundsen, Brage H.; Slørdahl, Stig H.; Olstad, Bjørn. High Frame Rate Tissue Doppler and Strain Rate Imaging. . | nb_NO |
dc.relation.haspart | Slørdahl, Stig H.; Bjærum, Steinar; Amundsen, Brage H.; Støylen, Asbjørn; Heimdal, Andreas; Rabben, Stein Inge; Torp, Hans. High frame rate strain rate imaging of the ventricular septum in healthy subjects. European Journal of Ultrasound. 14(2-3): 149-155, 2001. | nb_NO |
dc.title | Detection and Visualization of Moving Targets in Medical Ultrasound Imaging | nb_NO |
dc.type | Doctoral thesis | nb_NO |
dc.contributor.department | Norges teknisk-naturvitenskapelige universitet, Fakultet for informasjonsteknologi, matematikk og elektroteknikk, Institutt for datateknikk og informasjonsvitenskap | nb_NO |
dc.description.degree | dr.ing. | nb_NO |
dc.description.degree | dr.ing. | en_GB |