Vis enkel innførsel

dc.contributor.authorLie, Ingrid Anne
dc.contributor.authorKerklingh, Emma
dc.contributor.authorWesnes, Kristin
dc.contributor.authorvan Nederpelt, David R.
dc.contributor.authorBrouwer, Iman
dc.contributor.authorTorkildsen, Øivind
dc.contributor.authorMyhr, Kjell-Morten
dc.contributor.authorBarkhof, Frederik
dc.contributor.authorBø, Lars
dc.contributor.authorVrenken, Hugo
dc.date.accessioned2023-02-02T14:31:01Z
dc.date.available2023-02-02T14:31:01Z
dc.date.created2022-05-09T13:57:11Z
dc.date.issued2022
dc.identifier.citationEuropean Radiology. 2022, 32 (5), 3576-3587.en_US
dc.identifier.issn0938-7994
dc.identifier.urihttps://hdl.handle.net/11250/3048076
dc.description.abstractObjective - To determine whether reliable brain atrophy measures can be obtained from post-contrast 3D T1-weighted images in patients with multiple sclerosis (MS) using FreeSurfer. Methods - Twenty-two patients with MS were included, in which 3D T1-weighted MR images were obtained during the same scanner visit, with the same acquisition protocol, before and after administration of gadolinium-based contrast agents (GBCAs). Two FreeSurfer versions (v.6.0.1 and v.7.1.1.) were applied to calculate grey matter (GM) and white matter (WM) volumes and global and regional cortical thickness. The consistency between measures obtained in pre- and post-contrast images was assessed by intra-class correlation coefficient (ICC), the difference was investigated by paired t-tests, and the mean percentage increase or decrease was calculated for total WM and GM matter volume, total deep GM and thalamus volume, and mean cortical thickness. Results - Good to excellent reliability was found between all investigated measures, with ICC ranging from 0.926 to 0.996, all p values < 0.001. GM volumes and cortical thickness measurements were significantly higher in post-contrast images by 3.1 to 17.4%, while total WM volume decreased significantly by 1.7% (all p values < 0.001). Conclusion - The consistency between values obtained from pre- and post-contrast images was excellent, suggesting it may be possible to extract reliable brain atrophy measurements from T1-weighted images acquired after administration of GBCAs, using FreeSurfer. However, absolute values were systematically different between pre- and post-contrast images, meaning that such images should not be compared directly. Potential systematic effects, possibly dependent on GBCA dose or the delay time after contrast injection, should be investigated.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleThe effect of gadolinium-based contrast-agents on automated brain atrophy measurements by FreeSurfer in patients with multiple sclerosisen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.source.pagenumber3576-3587en_US
dc.source.volume32en_US
dc.source.journalEuropean Radiologyen_US
dc.source.issue5en_US
dc.identifier.doi10.1007/s00330-021-08405-8
dc.identifier.cristin2022734
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode2


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal