JavaScript is disabled for your browser. Some features of this site may not work without it.

The use of balconies for facade noise attenuation

Fjeld, Øyvind
Master thesis
Thumbnail
View/Open
no.ntnu:inspera:77039769:70438414.pdf (19.30Mb)
no.ntnu:inspera:77039769:70438414.zip (738.0Mb)
URI
https://hdl.handle.net/11250/2799888
Date
2021
Metadata
Show full item record
Collections
  • Institutt for elektroniske systemer [1865]
Abstract
Målet med masteroppgaven er å undersøke støydempningseffekten til balkonger på fasaden. Dette har blitt gjort gjennom feltmålinger og estimater ved bruk av Catt Acoustics, Nor96, retningslinje 517.521 av Byggforskserien og standarden ISO 12354-3.

Målingene viser at en balkong med kun harde overflater og tett rekkverk kan redusere lydtrykksnivået på fasaden bak balkongen med rundt 3 dB. Ved å installere treullsementplater i himlingen på bakongen kan lydreduksjonen økes med ytterligere 1-2 dB, til totalt 4-5 dB lydreduksjon sammenlignet med ikke å ha en balkong foran fasaden.

Sammenligning av resultatene viser en god overensstemmelse mellom målingene og estimatene i Catt Acoustics, mens Nor96 underestimerer skjermingen til balkongen. Retningslinje 517.521 overestimerer skjermingseffekten av en balkong uten tak sammelignet med målingene, spesielt for høye frekvenser. Estimatet gitt av ISO 12354-3 er ganske konservativt sammenlignet med måleresultatene, men kan anses som en indikasjon på den minste lydreduksjonen man kan forvente av balkongen.
 
The goal of the thesis is to investigate the ability of various types of balconies to reduce incoming noise on the building facade. This have been done through field measurements and estimates using Catt Acoustics, Nor96, ISO 12354-3 and guideline 517.521 from Byggforskserien.

The measurements show that the presence of a hard surfaced balcony with closed parapet can lead to an average sound reduction of around 3 dB across the facade behind the balcony compared to not having a balcony present. By also installing absorbing cement-bonded wood wool panels at the ceiling, an additional sound reduction of 1-2 dB, to a total SPL reduction of 4-5 dB compared to not having a balcony can be achieved.

Comparing the results show a good agreement between the measurements and estimates by Catt Acoustics, while Nor96 underestimates the screening effect of the balcony compared to the measurements. The 517.521 guideline overestimates on the sound reduction of a balcony without a ceiling compared to the measurements, particularly for high frequencies. The estimate by ISO 12354-3 is quite conservative compared to the measured results, but can be considered an indication of the minimum expected SPL reduction of a balcony.
 
Publisher
NTNU

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit
 

 

Browse

ArchiveCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsDocument TypesJournalsThis CollectionBy Issue DateAuthorsTitlesSubjectsDocument TypesJournals

My Account

Login

Statistics

View Usage Statistics

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit