dc.description.abstractOperating room (OR) is an indispensable department in a hospital, while its ventilation system is an important engineering solution to ensure safety for surgical procedures. Suitable ventilation system in the OR should be defined as using the minimum energy consumption and lifecycle cost to meet both the requirements of clean air for safe surgeries and comfort for occupants. Therefore, this study aims to develop a flexible evaluation framework on the suitability evaluation for ventilation system performance in ORs from a holistic view instead of one aspect only. To achieve the objective, we adopted analytic hierarchy process (AHP) and fuzzy comprehensive evaluation (FCE) methods and conducted suitability evaluation for two ORs with laminar airflow (LAF) and mixing ventilation (MV) system in St. Olavs Hospital, Norway. The evaluation includes seven indexes under three main aspects: ventilation effectiveness, energy consumption and users’ satisfaction. The comprehensive evaluation results are obtained through site measurements during mock surgeries, data collection and calculation as well as the questionnaire survey. Due to the unsatisfactory performance in energy consumption and thermal comfort indexes, the evaluation result of the suitability performance of the case OR with MV system was “unsuitable” while the one with LAF system was “suitable”, which reflects the situation that the energy consumption and thermal environment are sacrificed, although a clean and safe operation environment is guaranteed. The evaluation can provide basis for the commissioning of the ventilation system in the ORs of St. Olavs Hospital and provoke thinking of the ventilation system design and operation in the future.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.titleSuitability evaluation on laminar airflow and mixing airflow distribution strategies in operating rooms: A case study at St. Olavs Hospitalen_US
dc.typeJournal articleen_US
dc.description.versionsubmittedVersionen_US
dc.rights.holderThis is the authors' manuscript to an article published by Elsevieren_US
dc.source.journalBuilding and Environmenten_US
dc.identifier.doi10.1016/j.buildenv.2021.107677
dc.identifier.cristin1894328
cristin.ispublishedtrue
cristin.fulltextpreprint
cristin.qualitycode2


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel