Vis enkel innførsel

dc.contributor.authorKjønås, Didrik
dc.contributor.authorDahle, Gry
dc.contributor.authorSchirmer, Henrik
dc.contributor.authorMalm, Siri
dc.contributor.authorEidet, Jo
dc.contributor.authorAaberge, Lars
dc.contributor.authorSteigen, Terje
dc.contributor.authorAakhus, Svend
dc.contributor.authorBusund, Rolf
dc.contributor.authorRösner, Assami
dc.date.accessioned2019-08-07T11:38:28Z
dc.date.available2019-08-07T11:38:28Z
dc.date.created2019-06-24T10:44:49Z
dc.date.issued2019
dc.identifier.issn2053-3624
dc.identifier.urihttp://hdl.handle.net/11250/2607444
dc.description.abstractObjectives To investigate whether preoperative echocardiographic evaluation of ventricular function, especially right ventricular systolic and diastolic parameters including speckle-tracking analysis, could aid in the prediction of 30-day mortality after transcatheter aortic valve implantation (TAVI) in patients with aortic stenosis. Methods This is a prospective observational cohort study including 227 patients accepted for TAVI at the University Hospital of North Norway and Oslo University Hospital from February 2010 through June 2013. All patients underwent preoperative transthoracic echocardiography with retrospective speckle-tracking analysis. Primary endpoint was all-cause 30-day mortality. Results All-cause 30-day mortality was 8.7 % (n = 19). Independent predictors of 30-day mortality were systolic pulmonary arterial pressure (SPAP) > 60 mm Hg (HR: 7.7, 95% CI: 1.90 to 31.3), heart failure (HR: 2.9, 95% CI: 1.1 to 7.78), transapical access (HR: 3.8, 95% CI: 1.3 to 11.2), peripheral artery disease (HR: 6.0, 95% CI: 2.0 to 18.0) and body mass index (HR: 0.73, 95% CI: 0.61 to 0.87). C-statistic for the model generated was 0.91 (95% CI: 0.85 to 0.98). Besides elevated SPAP, no other echocardiographic measurements were found to be an independent predictor of early mortality. Conclusion Except for elevated systolic pulmonary artery pressure, our data suggests that clinical rather than echocardiographic parameters are useful predictors of 30-day mortality after TAVI.nb_NO
dc.language.isoengnb_NO
dc.publisherBMJ Publishing Groupnb_NO
dc.rightsNavngivelse-Ikkekommersiell 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/deed.no*
dc.titlePredictors of early mortality after transcatheter aortic valve implantationnb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.source.volume6nb_NO
dc.source.journalOpen heartnb_NO
dc.source.issue1nb_NO
dc.identifier.doi10.1136/openhrt-2018-000936
dc.identifier.cristin1707170
dc.description.localcode© Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJnb_NO
cristin.unitcode194,65,25,0
cristin.unitcode1920,6,0,0
cristin.unitnameInstitutt for sirkulasjon og bildediagnostikk
cristin.unitnameKlinikk for hjertemedisin
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse-Ikkekommersiell 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse-Ikkekommersiell 4.0 Internasjonal