Show simple item record

dc.contributor.authorKim, Jana
dc.contributor.authorKim, Eugene
dc.contributor.authorEuceda, Leslie R.
dc.contributor.authorMeyer, Dan E.
dc.contributor.authorLangseth, Karina
dc.contributor.authorBathen, Tone Frost
dc.contributor.authorMoestue, Siver Andreas
dc.contributor.authorHuuse, Else Marie
dc.date.accessioned2017-12-06T12:32:49Z
dc.date.available2017-12-06T12:32:49Z
dc.date.created2017-11-10T10:47:10Z
dc.date.issued2017
dc.identifier.issn1053-1807
dc.identifier.urihttp://hdl.handle.net/11250/2469391
dc.description.abstractBackground Steady state susceptibility contrast (SSC)-MRI provides information on vascular morphology but is a rarely used method. Purpose To investigate the utility of the ultrasmall superparamagnetic iron oxide particles (USPIOs) GEH121333 for measuring tumor response to bevacizumab and compare this with gadolinium-based DCE-MRI. Study Type Prospective preclinical animal model study. ANIMAL MODEL Mice bearing subcutaneous TOV-21G human ovarian cancer xenografts treated with bevacizumab (n = 9) or saline (n = 9). Field Strength/Sequence Imaging was performed on a 7T Bruker Biospec. For SSC-MRI with GEH121333 we acquired R1-maps (RARE-sequence with variable TR), R2-maps (multi-spin echo), and math formula-maps (multi-gradient echo). Additionally, R1 and R2 maps were measured on the days after USPIO injection. For DCE-MRI with gadodiamide we acquired 200 T1-weighted images (RARE-sequence). Assessment ΔR1, ΔR2, and math formula maps were computed from SSC-MRI. DCE-MRI was analysed using the extended Tofts model. Statistical Tests Results from pre- and 3 days posttreatment SSC-MRI were compared using paired-sample t-tests. Treatment and control groups were compared using independent sample t-tests. Performance of SSC- and DCE-MRI was compared using multivariate partial least squares discriminant analysis. Results Already one day after treatment and USPIO injection, R1 and R2 values were lower in treated (R1 = 0.49 ± 0.03s−1, R2 = 23.07 ± 1.49s−1) compared with control tumors (R1 = 0.52 ± 0.02s−1, R2 = 24.98 ± 1.01s−1), indicating lower USPIO accumulation. Posttreatment SSC-MRI displayed significantly decreased tumor blood volume (change in ΔR2 = -0.43 ± 0.26s−1, P = 0.001) and vessel density (change in Q = -0.032 ± 0.020s−1/3, P = 0.002). DCE-MRI showed among others lower Ktrans in treated tumors (control = 0.064 ± 0.011min−1, tx = 0.046 ± 0.008min−1, P = 0.002). Multivariate analysis suggests that SSC-MRI was slightly inferior to DCE-MRI in distinguishing treated from control tumors (accuracy = 75%, P = 0.058 versus 80%, P = 0.028), but a combination of both was best (accuracy = 85%; P = 0.003). Data Conclusion SSC-MRI with GEH121333 is sensitive to early (<24 h) and late changes in tumor vasculature. SSC-MRI and DCE-MRI provide complementary information and can be used to assess different aspects of vascular responses to anti-angiogenic therapies. Level of Evidence: 1 Technical Efficacy: Stage 2nb_NO
dc.language.isoengnb_NO
dc.publisherWileynb_NO
dc.titleMultiparametric Characterization of Response to Anti-angiogenic Therapy Using USPIO Contrast-enhanced MRI in Combination with Dynamic Contrast-enhanced MRInb_NO
dc.typeJournal articlenb_NO
dc.description.versionsubmittedVersionnb_NO
dc.source.journalJournal of Magnetic Resonance Imagingnb_NO
dc.identifier.doi10.1002/jmri.25898
dc.identifier.cristin1512873
dc.description.localcodeThis is the pre-peer reviewed version of the following article: [Multiparametric Characterization of Response to Anti-angiogenic Therapy Using USPIO Contrast-enhanced MRI in Combination with Dynamic Contrast-enhanced MRI], which has been published in final form at [http://onlinelibrary.wiley.com/doi/10.1002/jmri.25898/abstract]. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving.nb_NO
cristin.unitcode194,65,25,0
cristin.unitcode194,65,15,0
cristin.unitnameInstitutt for sirkulasjon og bildediagnostikk
cristin.unitnameInstitutt for klinisk og molekylær medisin
cristin.ispublishedfalse
cristin.fulltextpreprint
cristin.qualitycode2


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record