• norsk
    • English
  • English 
    • norsk
    • English
  • Login
View Item 
  •   Home
  • Fakultet for ingeniørvitenskap (IV)
  • Institutt for energi og prosessteknikk
  • View Item
  •   Home
  • Fakultet for ingeniørvitenskap (IV)
  • Institutt for energi og prosessteknikk
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Evaluation and Selection of the Precooling Stage for LNG Processes

Majzoub, Mohamad
Master thesis
Thumbnail
View/Open
566523_FULLTEXT01.pdf (4.738Mb)
566523_COVER01.pdf (184.1Kb)
566523_ATTACHMENT01.zip (21.62Mb)
URI
http://hdl.handle.net/11250/234882
Date
2012
Metadata
Show full item record
Collections
  • Institutt for energi og prosessteknikk [3301]
Abstract
As the worldwide energy consumption continues to grow, natural gas and especially LNG are expected to keep contributing significantly with this growth. More than 95% of the installed LNG facilities use a precooling cycle as the first stage of the liquefaction process. In this work, a technical comparison between different precooling cycles for LNG processes is carried out through computational simulations using Aspen HYSYS®. The aim is to provide future project developments with a clear idea of the technical advantages/disadvantages involved in the selection of the process for the precooling cycle in LNG processes. The precooling circuit is treated as a stand-alone cycle first and then implemented in an entire liquefaction process; the propane precooled mixed refrigerant (C3MR) and the mixed fluid cascade (MFC®) processes are used for this purpose. The parameters studied are essentially coefficient of performance (β), heat exchanger UA value, compressor power, suction volumetric flow and pressure ratio. Two cases, cold (6 °C) and warm (25 °C) climate conditions are considered for each study.A three stage propane precooled process was found to be the most energetically efficient among the studied cases, even better than a two stage mixed refrigerant process (C2/C3) for both climate conditions; however, the performance in terms of energy consumption is not the only parameter taken into account and therefore a selection chart is provided. Under warm climate conditions a propane precooling circuit showed to be the most recommended process. For cold climates, however, a two stage mixed refrigerant cycle reaching ca. -50 °C is the preferred alternative, since in this case the low ambient temperature gives the propane precooled process a low share in the entire process. Other cases, such as a single stage mixed refrigerant cycle and a mixed refrigerant including n-Butane are taken into account. Based on the obtained results, a new, highly efficient configuration for natural gas liquefaction has been suggested, it is to be implemented in relatively warm climate conditions. It consists of a MFC® process with modifications in the liquefaction cycle and a propane precooling instead of the mixed refrigerant circuit; no previous reference in the open literature was found for such arrangement.
Publisher
Institutt for energi- og prosessteknikk

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit
 

 

Browse

ArchiveCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsDocument TypesJournalsThis CollectionBy Issue DateAuthorsTitlesSubjectsDocument TypesJournals

My Account

Login

Statistics

View Usage Statistics

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit