dc.description.abstractHotels in India conventionally use diesel-fired hot water generators to meet hot water demands at 46°C. These are inefficient and also release high emissions. This study focuses on the energy saving and emission reduction potentials of a CO2 heat pump chiller system for such an application. An ejector-based system of 50 kW heating capacity is proposed for a typical hotel having a hot water demand of 40 m3 /day with a 5 m3 thermal storage tank (TST). The heat pump produces the hot water at 68°C which is stored in the proposed TST. As per the demand, the hot water from the TST will be supplied to two existing 5 m3 hot water supply tanks (one for rooms and the other for the kitchen) after being mixed with cold water to reach the required temperature (46°C). The system also supplements up to 3.2% of the cooling demand of the hotel by contributing chilled water at 7°C. The proposed system reduces the operating cost and CO2 emissions to approximately 10 and 30%, respectively of the existing set-up. Return on investment is found to be less than 2 years. Keywords: Ejector, R744, Transcritical, DHW, Thermal storage, Energy savingsen_US
dc.description.abstractAdvantage of CO2 heat pump chiller for the application in Indian hotelsen_US
dc.language.isoengen_US
dc.publisherInternational Institute of Refrigerationen_US
dc.relation.ispartofProceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023 - volume 4
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleAdvantage of CO2 heat pump chiller for the application in Indian hotelsen_US
dc.title.alternativeAdvantage of CO2 heat pump chiller for the application in Indian hotelsen_US
dc.typeChapteren_US
dc.description.versionacceptedVersionen_US
dc.rights.holder© Copyright 2023 International Institute of Refrigerationen_US
dc.source.pagenumber1274-1281en_US
dc.identifier.cristin2186382
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal