dc.description.abstractHotels in India conventionally use diesel-fired hot water generators to meet hot water demands at 46°C. These are inefficient and also release high emissions. This study focuses on the energy saving and emission reduction potentials of a CO2 heat pump chiller system for such an application. An ejector-based system of 50 kW heating capacity is proposed for a typical hotel having a hot water demand of 40 m3 /day with a 5 m3 thermal storage tank (TST). The heat pump produces the hot water at 68°C which is stored in the proposed TST. As per the demand, the hot water from the TST will be supplied to two existing 5 m3 hot water supply tanks (one for rooms and the other for the kitchen) after being mixed with cold water to reach the required temperature (46°C). The system also supplements up to 3.2% of the cooling demand of the hotel by contributing chilled water at 7°C. The proposed system reduces the operating cost and CO2 emissions to approximately 10 and 30%, respectively of the existing set-up. Return on investment is found to be less than 2 years. Keywords: Ejector, R744, Transcritical, DHW, Thermal storage, Energy savingsen_US
dc.description.abstractAdvantage of CO2 heat pump chiller for the application in Indian hotelsen_US
dc.language.isoengen_US
dc.publisherInternational Institute of Refrigerationen_US
dc.relation.ispartofProceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023 - volume 4
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleAdvantage of CO2 heat pump chiller for the application in Indian hotelsen_US
dc.title.alternativeAdvantage of CO2 heat pump chiller for the application in Indian hotelsen_US
dc.typeChapteren_US
dc.description.versionacceptedVersionen_US
dc.rights.holder© Copyright 2023 International Institute of Refrigerationen_US
dc.source.pagenumber1274-1281en_US
dc.identifier.cristin2186382
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal