dc.description.abstractDenne oppgaven har forsket på startstrømmer fra LED-drivere og metoder for å øke antall LED-armaturer på en kurs, samt hvilken innvirkning kabellengde og nettsystem har. Den har også undersøkt om utskifting av lysstoffrør til LED-lysrør vil introdusere problemer med startstrøm på eksisterende anlegg. Målinger av startstrøm og stasjonær strøm ble gjennomført på LED-anlegg ved NTNU og Studentersamfundet i Trondheim. Resultatet indikerer at startstrømsdataen for armaturene stemmer godt. Målingene viste at anleggene er overdimensjonert med tanke på nominell strøm. På Studentersamfundet ble tre kurser sammenkoblet til ett vern og målt til en startstrøm på 728A, som førte til at vernet løste ut hver gang. En startstrømbegrenser ble testet og resultatet viste at den begrenset strømmen ned til 48A, og muliggjorde reduksjon av tre kurser til én uten at vernet løste ut. Et nullgjennomgangsrelé ble også testet og startstrømmen ble betydelig redusert. Vernet løste derimot fortsatt ut og reléet fungerte ikke like godt som begrenseren. Resultatene indikerte imidlertid at reléet kan fungere ved lavere strømmer. Utløserkarakteristikken til C16-vern ble testet og sammenlignet med impulsutløserkurvene fra Siemens, ABB og Eaton. Resultatene viste at Siemens-kurven stemte godt overens med vernet, mens ABBs kurve var mindre treffsikker og Eatons kurve stemte dårlig. En generell kurve ble utviklet og testet opp mot databladet til 109 ulike armaturer. Hensikten var å se om kurven tillater flere armaturer per kurs enn databladet oppgir. Resultatene varierte veldig mellom ulike armaturer, og metoden egner seg derfor ikke til å dimensjonere LED-anlegg på generell basis. Det kunne ikke påvises betydelig forskjell i startstrømmen på LED-lysrør, sammenlignet med konvensjonelle lysrør. Det kunne heller ikke påvises noe forskjell på startstrømmene med IT- eller TN-nett. Målingen viste at kabellengde kan være med på å dempe størrelsen på startstrømmen.
dc.description.abstractThis thesis has investigated inrush currents from LED drivers and methods to increase the number of LED luminaires on a single circuit. Additionally, the study has examined whether replacing fluorescent tubes with LED tubes would introduce issues with inrush current in existing installations. The influence of cable length and different power distribution systems on the inrush current was also considered. Measurements of inrush current and steady-state current were conducted on LED installations at NTNU and Studentersamfundet in Trondheim. The results indicates that the given inrush current data for the LED-luminaires are correct. The measurements revealed that the installations are over-dimensioned in relation to the nominal current. At Studentersamfundet, three circuits were interconnected to a single circuit breaker, resulting in a measured starting current of 728A, which caused the circuit breaker to trip every time. An inrush current limiter was tested. The results showed that it successfully limited the current to 48A, allowing the reduction of three circuits to one without tripping the circuit breaker at Studentersamfundet. A zero-crossing relay was also tested, and it significantly reduced the inrush current. However, the circuit breaker still tripped, indicating that the relay did not perform as effectively as the inrush current limiter. Nevertheless, the results suggested that the relay may function well at lower inrush currents. The tripping characteristics of C16 circuit breakers were tested and compared to the impulse tripping curves from Siemens, ABB, and Eaton. The results showed that the Siemens curve closely matched their circuit breaker, while ABB's curve was less accurate, and Eaton's curve did not coincide. A general curve was developed and tested against the datasheets of 109 different luminaires. The purpose was to determine if the curve allows for more luminaires per circuit breaker than stated in the datasheets. The results varied greatly among different luminaires, and therefore, this method is not suitable for general dimensioning of LED installations. The results of the experiment conducted on LED and fluorescent tubes suggest that there is not a considerable difference between the tubes in inrush currents. Nor could it be proven that there was a difference in inrush current between IT and TN power systems. The experiments did however prove that increasing the cable length reduces the inrush current.
dc.languagenob
dc.publisherNTNU
dc.titleDimensjonering av LED-anlegg med svært høye startstrømmer
dc.typeBachelor thesis