Vis enkel innførsel

dc.contributor.advisorSeidu, Razak
dc.contributor.advisorPaus Haukeland, Ranveig
dc.contributor.authorAsefi, Hamed
dc.contributor.authorShengeb Nesraldin, Bilal
dc.date.accessioned2023-07-06T17:21:07Z
dc.date.available2023-07-06T17:21:07Z
dc.date.issued2023
dc.identifierno.ntnu:inspera:146720110:149056256
dc.identifier.urihttps://hdl.handle.net/11250/3076936
dc.descriptionFull text not available
dc.description.abstractFremmedvann i avløpssystem er en av de største problemer i norsk samfunn. dette er vann som er ikke skal være i avløpssystemet, men likevel finner veien inn i spillvannledninger gjennom utette skjøter, og kumlokk, sprekker i rør og kummer, samt feilkoblinger. Spillvannledning med mye fremmedvann medfører unødvendig store forurensingsutslipp og større kostander til drifte og større investeringer i avløpsanlegget. Det økonomiske går ut på at avløpsanlegget må dimensjoneres for større mengde av vann enn det har vært nødvendig uten fremmedvannet. I tillegg kostnader for å rense det ekstra vannet. I denne oppgaven er fremmedvann definert som alt vann som ikke ment å være i avløpssystemet, et system som består av ledninger, kummer, pumper med mer. For å fullføre denne oppgaven ble foretatt en grundig studie av området ved å studere området godt ved å gjennomføre datainnsamling både fra kommune og MIWAS. Deretter ble det utført tørr- og våtbefaringer for å undersøke området der det var mistanke om innlekking. I området er et separatsystem der spillvann- og overvannsledningene var delt i to, men begge var koblet til samme kum. Dette system er kjent for felleskummer. Gjennom bildene og videoene ble det påviste tilstandene nøy dokumentert, inkludert synlig tegn på fremmedvann i kummene og tydelig lekkasjer. Det ble også gjennomført en sammenligning av vannstanden i avløpssystemet med tidspunktene for når pumpestasjonen gikk overløp. Resultatene viste at hver gang vannstanden var for høy, oppstod gikk pumpestasjonen i overløp. Det ble konkludert med at innlekking i kummene som førte til overløp i pumpestasjon, derfor ble det anbefalt å fjerne felleskummer og etablere et separatsystem i Sone B. det mistankes lekkasje fra overvannledning til spillvann, og vannet fra overvannsledningen i sone A forsvinner i sone B. Ved å sammenligne disse med grafen som viser vannstandsnivået ser man en tydelig sammenheng. Dette tyder på at når vannstanden i sjøen er høy, oppstår det overløp i pumpestasjon. For å unngå pumpestasjon går i overløp, er det flere tiltak som kan vurderes. F.eks. dreneringssystem. dette kan inkludere bygging av reservoarer eller kanaler for å lede overskuddsvannet bort fra pumpestasjonen og redusere belastningen på systemet.
dc.description.abstractInflow of extraneous water into the sewer system is one of the biggest problems in Norwegian society. This refers to water that should not be in the sewer system but still finds its way into wastewater pipes through loose joints, manhole covers, cracks in pipes and manholes, as well as improper connections. Wastewater pipes with significant extraneous water result in unnecessary pollution discharges and higher operating costs, as well as increased investments in the sewage infrastructure. The economic impact lies in the fact that the sewage system needs to be dimensioned to accommodate a larger volume of water than would be necessary without the extraneous water, in addition to the costs associated with treating the extra water. In this study, extraneous water is defined as any water that is not intended to be in the sewer system, which comprises pipes, manholes, pumps, and more. To complete this task, a thorough study of the area was conducted by extensively examining the area and collecting data from both the municipality and MIWAS. Subsequently, dry, and wet inspections were carried out to investigate areas suspected of leakage. The area in question has a separate system where wastewater and stormwater pipes are divided, but both are connected to the same manhole. This system is known for shared manholes. Using photos and videos, the observed conditions were accurately documented, including visible signs of extraneous water in the manholes and clear indications of leaks. A comparison was also made between the water levels in the sewer system and the times when the pumping station went into overflow. The results showed that every time the water level was too high, the pumping station experienced overflow. It was concluded that leakage in the manholes was causing the overflow in the pumping station. Therefore, it was recommended to remove the shared manholes and establish a separate system in Zone B. There is a suspected leakage from the stormwater pipe to the wastewater system, and the water from the stormwater pipe in Zone A disappears in Zone B. By comparing these findings with the graph illustrating the water level, a clear correlation can be observed. This suggests that when the sea level is high, overflow occurs in the pumping station. To prevent the pumping station from going into overflow, several measures can be considered, such as implementing a drainage system. This could involve constructing reservoirs or channels to divert excess water away from the pumping station and reduce the burden on the system.
dc.languagenob
dc.publisherNTNU
dc.titleKILDEOPPSØKING AV FREMMEDVANN PÅ GYSSETAND
dc.typeBachelor thesis


Tilhørende fil(er)

FilerStørrelseFormatVis

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel