dc.description.abstractTeknologisk utvikling har bidratt til bedre blodsukkerregulering i diabetesbehandlingen. De mest avanserte type insulinpumpene er hybrid lukkede sløyfesystemer. Formålet med systemene er å forsøke å oppnå behandlingsmålene og gi en enklere hverdag for diabetespasienter. I Norge i dag er det to hybrid lukkede sløyfesystemer tilgjengelig; Minimed 780G med SmartGuard-funksjon og Tandem t:slim X2 med Control-IQ teknologi. De to systemene opererer med ulike algoritmer, men har samme behandlingsmål. Personer med diabetes type 1 kan låne disse systemene gjennom regionale helseforetak. Minimed 780G med SmartGuard-funksjon er førstevalg på sykehusanbudet, og Tandem t:slim X2 med Control-IQ teknologi er andrevalg. Det finnes lite forskning som har sammenlignet disse to systemene når det gjelder blodsukkerregulering og opplevd brukskvalitet. Denne masteroppgaven har sammenlignet Minimed 780G med SmartGuard-funksjon og Tandem t:slim X2 med Control-IQ teknologi når det gjelder blodsukkerregulering og opplevd brukskvalitet. Det ble benyttet en kombinasjon av kvalitativ og kvantitativ metode. Blodsukkerreguleringen ble sammenlignet ut ifra nedlastet data fra insulinpumpene. Opplevd brukskvalitet ble sammenlignet med bruk av to ulike kvantitative spørreskjema; SUS-skjema og et egenkomponert spørreskjema. Det ble også utført tre semistrukturerte intervju. Resultater fra masteroppgaven viser at respondentene fra begge gruppene var godt fornøyde med systemene når det gjaldt opplevd brukskvalitet. Det var lite som skilte resultatene mellom brukerne av de ulike systemene når det gjelder opplevd brukskvalitet. Begge systemene oppfylte anbefalingen til den internasjonale konsensus, både når det gjaldt tid i målområdet, tid under målområdet og variasjonskoeffisient. Det var også lite som skiller blodsukkerreguleringen mellom systemene. Vi tror denne masteroppgave kan bidra til økt kunnskap blant helsepersonell, og gjøre det enklere å vurdere hvilken insulinpumpe som kan passe den enkelte pasients behov. Vi håper masteroppgaven kan bidra til mer forskning omkring blodsukkerregulering og opplevd brukskvalitet på hybrid lukkede sløyfesystemer.
dc.description.abstractTechnological development has contributed to improved blood sugar regulation. The most advanced insulin pumps are hybrid closed loop. The purpose of the systems is to achieve treatment targets and simplify the day-to-day life of diabetes patients. As of today, two hybrid closed loop systems are available; Minimed 780G with SmartGuard function and Tandem t:slim X2 with Control-IQ technology. The two systems operate with unique algorithms but have the same treatment goal. Individuals with type 1 diabetes can borrow these systems through regional healthcare services. Minimed 780G with SmartGuard function is the preferred tenderer and Tandem t:slim X2 with Control-IQ technology is second. There is little research that has compared the two systems regarding blood sugar regulation and usability. This thesis has compared Minimed 780G with SmartGuard function and Tandem t:slim X2 with Control-IQ technology with regards to blood sugar regulation and usability A combination of qualitative and quantitative methods were used. Blood sugar regulation was compared based on downloaded data from the pumps. Usability was compared by using two separate questionnaires; SUS-questionnaire and a self composed questionnaire. Three semi structured interviews were also performed. Results from the thesis show that respondents from both groups are satisfied with the systems with regards to usability. Results did not show any significant difference between the two in terms of usability. Both systems fulfill the recommendations from international consensus groups in terms of time in range, time below range and variation coefficient. There were no significant differences between the systems in terms of blood sugar regulation. We believe that this thesis can contribute to increasing knowledge among healthcare professionals and help them decide which insulin pump is best suited for a patient. We hope that this thesis can contribute to increasing research on blood sugar regulation and usability on hybrid closed loop.
dc.languagenob
dc.publisherNTNU
dc.titleMinimed 780G med SmartGuard-funksjon versus Tandem t:slim X2 med Control-IQ teknologi En undersøkelse av opplevd brukskvalitet og blodsukkerregulering
dc.typeMaster thesis


Tilhørende fil(er)

FilerStørrelseFormatVis

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel