Show simple item record

dc.contributor.authorØstvik, Andreas
dc.contributor.authorSmistad, Erik
dc.contributor.authorEspeland, Torvald
dc.contributor.authorBerg, Erik Andreas Rye
dc.contributor.authorLøvstakken, Lasse
dc.date.accessioned2022-04-19T09:23:56Z
dc.date.available2022-04-19T09:23:56Z
dc.date.created2018-10-06T10:47:01Z
dc.date.issued2018
dc.identifier.citationLecture Notes in Computer Science. 2018, 11045 309-316.en_US
dc.identifier.issn0302-9743
dc.identifier.urihttps://hdl.handle.net/11250/2991260
dc.description.abstractRecent studies in the field of deep learning suggest that motion estimation can be treated as a learnable problem. In this paper we propose a pipeline for functional imaging in echocardiography consisting of four central components, (i) classification of cardiac view, (ii) semantic partitioning of the left ventricle (LV) myocardium, (iii) regional motion estimates and (iv) fusion of measurements. A U-Net type of convolutional neural network (CNN) was developed to classify muscle tissue, and partitioned into a semantic measurement kernel based on LV length and ventricular orientation. Dense tissue motion was predicted using stacked U-Net architectures with image warping of intermediate flow, designed to tackle variable displacements. Training was performed on a mixture of real and synthetic data. The resulting segmentation and motion estimates was fused in a Kalman filter and used as basis for measuring global longitudinal strain. For reference, 2D ultrasound images from 21 subjects were acquired using a GE Vivid system. Data was analyzed by two specialists using a semi-automatic tool for longitudinal function estimates in a commercial system, and further compared to output of the proposed method. Qualitative assessment showed comparable deformation trends as the clinical analysis software. The average deviation for the global longitudinal strain was (−0.6±1.6 −0.6±1.6 )% for apical four-chamber view. The system was implemented with Tensorflow, and working in an end-to-end fashion without any ad-hoc tuning. Using a modern graphics processing unit, the average inference time is estimated to (115±3 115±3 ) ms per frame.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.titleAutomatic Myocardial Strain Imaging in Echocardiography Using Deep Learningen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionacceptedVersionen_US
dc.source.pagenumber309-316en_US
dc.source.volume11045en_US
dc.source.journalLecture Notes in Computer Scienceen_US
dc.identifier.doi10.1007/978-3-030-00889-5_35
dc.identifier.cristin1618327
dc.relation.projectNorges forskningsråd: 237887en_US
cristin.unitcode194,65,25,0
cristin.unitnameInstitutt for sirkulasjon og bildediagnostikk
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record