• norsk
    • English
  • norsk 
    • norsk
    • English
  • Logg inn
Vis innførsel 
  •   Hjem
  • Øvrige samlinger
  • Publikasjoner fra CRIStin - NTNU
  • Vis innførsel
  •   Hjem
  • Øvrige samlinger
  • Publikasjoner fra CRIStin - NTNU
  • Vis innførsel
JavaScript is disabled for your browser. Some features of this site may not work without it.

Effects of Power Take-Off Damping and Model Scaling on the Hydrodynamic Performance of Oscillating Water Column Device

Ashlin, S John; Sannasiraj, S A; Sundar, Vallam; Kamath, Arun; Bihs, Hans
Chapter
Published version
Åpne
Ashlin_ICOE2018_OWC.pdf (Låst)
Permanent lenke
https://hdl.handle.net/11250/2988411
Utgivelsesdato
2019
Metadata
Vis full innførsel
Samlinger
  • Institutt for bygg- og miljøteknikk [5092]
  • Publikasjoner fra CRIStin - NTNU [41732]
Originalversjon
10.1007/978-981-13-3134-3_60
Sammendrag
A systematic numerical investigation on the hydrodynamic performance of an oscillating water column (OWC) system for different damping values from the power take-off (PTO) device and at different model scales has been studied. Further, an experimental programme was devised with a Froude model scale of 1:12 in a shallow wave flume by representing PTO damping by varying the air orifice ratio, a/A [ratio of air orifice area (a) to plan area (A)]. In the case of numerical investigation, simulation was carried out in the computational fluid dynamics (CFD) model, REEF3D. Herein, the equivalent PTO damping on the OWC chamber is represented by the porous media flow relation. First, the numerical results are validated by comparing with the laboratory measurements for five different PTO damping. Second, following the validation stage, the open-source numerical model is used to evaluate model scale effects on the hydrodynamic performance of the OWC by comparing hydrodynamic parameters of four different model scales from 1:12 to full scale. In this paper, the influence of PTO damping and model scales on the variation of pressure behind the lip wall, air pressure, and hydrodynamic efficiency is studied. The results are reported for different relative water depths. Since the air is modelled as incompressible, the effect of scaling on the hydrodynamic performance of OWC is found with negligible variation.
Utgiver
Springer
Opphavsrett
The published version of the article will not be available due to copyright restrictions

Kontakt oss | Gi tilbakemelding

Personvernerklæring
DSpace software copyright © 2002-2019  DuraSpace

Levert av  Unit
 

 

Bla i

Hele arkivetDelarkiv og samlingerUtgivelsesdatoForfattereTitlerEmneordDokumenttyperTidsskrifterDenne samlingenUtgivelsesdatoForfattereTitlerEmneordDokumenttyperTidsskrifter

Min side

Logg inn

Statistikk

Besøksstatistikk

Kontakt oss | Gi tilbakemelding

Personvernerklæring
DSpace software copyright © 2002-2019  DuraSpace

Levert av  Unit