Vis enkel innførsel

dc.contributor.authorYe, Zuliang
dc.contributor.authorWang, Yikai
dc.contributor.authorZendehboudi, Alireza
dc.contributor.authorHafner, Armin
dc.contributor.authorCao, Feng
dc.date.accessioned2022-03-04T11:51:38Z
dc.date.available2022-03-04T11:51:38Z
dc.date.created2021-12-17T11:16:07Z
dc.date.issued2021
dc.identifier.issn0140-7007
dc.identifier.urihttps://hdl.handle.net/11250/2983127
dc.description.abstractThe utilization of fluted inner tube in tube-in-tube heat exchangers is an effective way to improve the heat transfer performance. Based on the segmented model, the performance of a fluted tube-in-tube gas cooler (FTGC) in the transcritical CO2 heat pump water heater was studied in this paper. The simulation model was validated and adopted to numerically investigate the effects of different parameters on the heat transfer performance of the gas cooler, which was compared to the smooth tube-in-tube gas cooler (STGC) with the same geometric parameters. The results showed that the FTGC had higher heat transfer capacity in most conditions. The heat transfer rate first increased and then decreased as the CO2 inlet pressure increased. The temperature difference at the pinch point in the FTGC was lower than that in the STGC. In the FTGC, the pinch point position was mainly influenced by the CO2 inlet pressure and water inlet and outlet temperatures. Regarding the system COP, the improvement of maximum COP could be up to 29.41% by using the FTGC compared to STGC when the water inlet temperature was 10°C and the water outlet temperature was 80°C. However, when the water inlet temperature was 40°C, the improvement of COP could be impaired to 12.98%. Through changing the designs of the FTGC with the fixed total heat transfer area, when the water inlet and outlet temperatures were 10°C and 60°C, the highest maximum COP could be obtained with the design used in the experiments.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.no*
dc.titleInvestigation on the performance of fluted tube-in-tube gas cooler in transcritical CO2 heat pump water heateren_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionacceptedVersionen_US
dc.rights.holderThis is the authors' accepted manuscript to an article published by Elsevier. Locked until 15.12.2023 due to copyright restrictions. The AAM is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/en_US
dc.source.journalInternational journal of refrigerationen_US
dc.identifier.doi10.1016/j.ijrefrig.2021.12.011
dc.identifier.cristin1969837
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal