Show simple item record

dc.contributor.authorHelgerud, Jan
dc.contributor.authorØiestad, Britt Elin
dc.contributor.authorWang, Eivind
dc.contributor.authorHoff, Jan
dc.date.accessioned2020-09-01T12:54:01Z
dc.date.available2020-09-01T12:54:01Z
dc.date.created2019-11-21T17:17:21Z
dc.date.issued2019
dc.identifier.citationEuropean Journal of Applied Physiology. 2019, 119 (11-12), 2589-2598.en_US
dc.identifier.issn1439-6319
dc.identifier.urihttps://hdl.handle.net/11250/2675870
dc.description.abstractBased on the strong linear relationship between heart rate (HR) and oxygen consumption, the Åstrand–Ryhming cycle ergometer test (Astrand and Ryhming in J Appl Physiol 7:218–221, 1954) is a widely used submaximal test to predict whole body maximal oxygen consumption (V˙O2max). However, a similar test predicting peak oxygen consumption (V˙O2peak) in the upper extremities is not established, and may be very useful for individuals unable to use their lower extremities or/and if separation of upper extremity aerobic capacity is sought after. Thus, the aim of the current study was to develop a submaximal test predicting V˙O2peak in arm-cycling. Forty-nine healthy volunteers (25 women: 38 ± 13 years; 24 men: 39 ± 12 years) tested arm-cycle V˙O2peak on a protocol with 4-min, 21-W increments to exhaustion. The data were contrasted to treadmill V˙O2max values. Arm-cycle V˙O2peak was 66 ± 8% of V˙O2max (r = 0.92, p < 0.001; women: 1.9 ± 0.4 L min−1; men: 3.0 ± 0.7 L min−1). Arm-cycle HR and %V˙O2 exhibited correlations of r = 0.79 and r = 0.78 for women and men, respectively, while corresponding correlations between work rate and V˙O2 were r = 0.95 (women) and r = 0.89 (men) (all p < 0.001). Arm-cycle V˙O2peak prediction revealed a standard error of estimate (SEE) of 11.2% (women) and 10.2% (men), and was primarily due to individual arm-cycle maximal HR (women: 173 ± 13 beats min−1; men: 174 ± 10 beats min−1; correction factor: 5–7%). In conclusion, from a single 4-min stage of submaximal arm cycling, V˙O2peak can be predicted with a SEE of 10–11%. The arm-cycle test may have important value for individuals who rely on arms in sports and occupations, and for patients with lower extremity disabilities.en_US
dc.language.isoengen_US
dc.publisherSpringer Verlagen_US
dc.titlePrediction of upper extremity peak oxygen consumption from heart rate during submaximal arm cycling in young and middle-aged adultsen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.source.pagenumber2589-2598en_US
dc.source.volume119en_US
dc.source.journalEuropean Journal of Applied Physiologyen_US
dc.source.issue11-12en_US
dc.identifier.doi10.1007/s00421-019-04225-3
dc.identifier.cristin1750700
dc.description.localcodeThis article will not be available due to copyright restrictions (c) 2019 by Springer Verlag.en_US
cristin.unitcode194,65,25,0
cristin.unitcode1920,5,0,0
cristin.unitnameInstitutt for sirkulasjon og bildediagnostikk
cristin.unitnameKlinikk for fysikalsk medisin og rehabilitering
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record