Vis enkel innførsel

dc.contributor.authorLopez Zazueta, Claudia
dc.contributor.authorStavdahl, Øyvind
dc.contributor.authorFougner, Anders Lyngvi
dc.date.accessioned2020-01-03T13:27:16Z
dc.date.available2020-01-03T13:27:16Z
dc.date.created2019-12-28T23:48:01Z
dc.date.issued2019
dc.identifier.citationIFAC-PapersOnLine. 2019, 52 (26), 219-224.nb_NO
dc.identifier.issn2405-8963
dc.identifier.urihttp://hdl.handle.net/11250/2634835
dc.description.abstractThe design of a model-based control method for an Artificial Pancreas requires a relatively simple and identifiable mathematical model to control glucose levels through hormone delivery. In this work we introduce new, simple nonlinear models to simulate data from experiments where insulin boluses are administrated in the peritoneal cavity. The models account for the delay between insulin administration and its nonlinear transport to other compartments. They were calibrated using experimental data from pigs. The results show that the suggested models are able to describe the data well, with average BIC value of 145. Moreover, the new models were compared with a common linear model which was not able to describe the data well, with BIC value of 920. They were also compared with a common nonlinear model which failed to represent insulin increases in the data and had BIC value of 637. Finally, profile likelihoods were applied for assessing the identifiability of one of the new models.nb_NO
dc.language.isoengnb_NO
dc.publisherInternational Federation of Automatic Control (IFAC)nb_NO
dc.subjectParameterestimeringnb_NO
dc.subjectParameter estimationnb_NO
dc.subjectType 1 diabetesnb_NO
dc.subjectSystemidentifikasjonnb_NO
dc.subjectSystem identificationnb_NO
dc.subjectMedisinsk kybernetikknb_NO
dc.subjectMedical cyberneticsnb_NO
dc.titleSimple Nonlinear Models for Glucose-Insulin Dynamics: Application to Intraperitoneal Insulin Infusionnb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.subject.nsiVDP::Medisinsk teknologi: 620nb_NO
dc.subject.nsiVDP::Medical technology: 620nb_NO
dc.source.pagenumber219-224nb_NO
dc.source.volume52nb_NO
dc.source.journalIFAC-PapersOnLinenb_NO
dc.source.issue26nb_NO
dc.identifier.doi10.1016/j.ifacol.2019.12.261
dc.identifier.cristin1764132
dc.relation.projectNorges forskningsråd: 248872nb_NO
dc.description.localcode© 2019, IFAC (International Federation of Automatic Control) Hosting by Elsevier Ltd.nb_NO
cristin.unitcode194,63,25,0
cristin.unitnameInstitutt for teknisk kybernetikk
cristin.ispublishedtrue
cristin.fulltextpreprint
cristin.fulltextoriginal
cristin.fulltextpostprint
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel