Show simple item record

dc.contributor.authorKaspersen, Benedicte
dc.contributor.authorLohne, Jardar
dc.contributor.authorBohne, Rolf André
dc.date.accessioned2016-12-01T10:16:18Z
dc.date.accessioned2017-01-17T14:04:14Z
dc.date.available2016-12-01T10:16:18Z
dc.date.available2017-01-17T14:04:14Z
dc.date.issued2016
dc.identifier.citationEnergy Procedia 2016, 96:5-16nb_NO
dc.identifier.issn1876-6102
dc.identifier.urihttp://hdl.handle.net/11250/2427544
dc.description.abstractBuilding tall typically requires a different operational energy demand and additional material. The purpose of this article is to analyze the adaption of technical systems to increased building height with particular interest to CO2 emissions. The analysis is carried out through a Life Cycle Assessment, using Simapro. This study covers only commercial buildings ranging from 4 to 21 floors. The scope of the study is limited to cradle-to-gate. The calculation model is based on the material quantities of the different components in the technical systems and corresponding material emission factors. The results show that plumbing, HVAC and elevators in total cause a minimal increase of greenhouse gas emissions per square meter area with increased building height. The greenhouse gas emission trend up to 12 floors varies slightly and is highly dependent upon the technical system solution. From 12 to 21 floors there is a small increase in GHG emissions. As the change in greenhouse gas emissions per square meter appears to be minimal, it has been concluded in this study that the change in GHG emissions caused by technical installations is negligible.nb_NO
dc.language.isoengnb_NO
dc.publisherElseviernb_NO
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.no*
dc.titleExploring the CO2-Impact for Building Height; A Study on Technical Building Installationsnb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.date.updated2016-12-01T10:16:18Z
dc.source.pagenumber5-16nb_NO
dc.source.volume96nb_NO
dc.source.journalEnergy Procedianb_NO
dc.identifier.doi10.1016/j.egypro.2016.09.089
dc.identifier.cristin1407012
dc.description.localcode© 2016 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)nb_NO


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal