Vis enkel innførsel

dc.contributor.authorLiu, Hongbo
dc.contributor.authorSummers, Natalie Maria
dc.contributor.authorChen, Yi-Chun
dc.contributor.authorLøvås, Håvard Snefjellå
dc.contributor.authorJohnsen, Geir
dc.contributor.authorKoestner, Daniel Warren
dc.contributor.authorSætre, Camilla
dc.contributor.authorHamre, Børge
dc.date.accessioned2024-05-27T12:23:28Z
dc.date.available2024-05-27T12:23:28Z
dc.date.created2024-05-26T18:04:17Z
dc.date.issued2024
dc.identifier.issn1094-4087
dc.identifier.urihttps://hdl.handle.net/11250/3131564
dc.description.abstractIn situ spectral reflectance initially captured at high spatial resolution with underwater hyperspectral imaging (UHI) is effective for classification and quantification in oceanic biogeochemical studies; however, the measured spectral radiance is rarely used as an absolute quantity due to challenges in calibration of UHI instruments. In this paper, a commercial UHI instrument was calibrated for radiometric flat field response and pixelwise immersion effect to support in situ measurement of absolute spectral radiance. The radiometric and immersion factor calibrations of the UHI instrument were evaluated quantitatively through comparative experiments with a spectroradiometer and a spectrometer. Results show that the immersion factor of the center pixel of the tested UHI instrument was 1.763 in pure water at 600 nm, and the averaged difference in immersion factor between the center and edge pixel of the UHI instrument in the visible light band was only 1∼3% across its half angle field of view of 35° in air. The new calibration coefficients were further used to calculate the spectral radiance of transmitted sunlight through ice algae clusters in sea ice measured by the UHI instrument during an Arctic under-ice bio-optical survey.en_US
dc.language.isoengen_US
dc.publisherOptical Publishing Groupen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titlePixelwise immersion factor calibration for underwater hyperspectral imaging instrumentsen_US
dc.title.alternativePixelwise immersion factor calibration for underwater hyperspectral imaging instrumentsen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionpublishedVersionen_US
dc.source.pagenumber19854-19880en_US
dc.source.volume32en_US
dc.source.journalOptics Expressen_US
dc.source.issue11en_US
dc.identifier.doi10.1364/OE.523641
dc.identifier.cristin2270905
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode2


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal