Vis enkel innførsel

dc.contributor.authorSkraastad, Erlend Johan
dc.contributor.authorBorchgrevink, Petter Chr.
dc.contributor.authorOpøyen, Lillian Asbøll
dc.contributor.authorRæder, Johan
dc.date.accessioned2024-03-04T09:40:38Z
dc.date.available2024-03-04T09:40:38Z
dc.date.created2023-08-25T14:45:11Z
dc.date.issued2023
dc.identifier.citationJournal of clinical monitoring and computing. 2023, .en_US
dc.identifier.issn1387-1307
dc.identifier.urihttps://hdl.handle.net/11250/3120823
dc.description.abstractTo evaluate objective time consumption and how nurses perceived introducing wireless patient monitoring (WPM) and a validated score on patient quality and safety, the Efficacy Safety Score (ESS), at a mixed surgery ward. After fulfilling a randomised controlled trial combining the ESS and WPM, we addressed time consumption and conducted a questionnaire survey among nurses who participated in the study. The questionnaire appraised the nurses’ evaluation of introducing these tools for postoperative management. Of 28 invited nurses, 24 responded to the questionnaire, and 92% reported the ESS and WPM-systems to increase patient safety and quality of care. 67% felt the intervention took extra time, but objective workload measurements revealed reduced time to 1/3 using ESS and WPM compared to standard manual assessment. Improved confidence when using the systems was reported by 83% and improved working situation by 75%. In a test situation to measure time consumption, the ESS and pre-attached WPM-systems require less time than the conventional standard of care, and may allow for more frequent clinical monitoring at the post-surgical ward. The combination of the ESS and the WPM systems was perceived as positive by participating nurses and further clinical development and research is warranted.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleWireless patient monitoring and Efficacy Safety Score in postoperative treatment at the ward: evaluation of time consumption and usabilityen_US
dc.title.alternativeWireless patient monitoring and Efficacy Safety Score in postoperative treatment at the ward: evaluation of time consumption and usabilityen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionpublishedVersionen_US
dc.source.pagenumber0en_US
dc.source.journalJournal of clinical monitoring and computingen_US
dc.identifier.doi10.1007/s10877-023-01053-x
dc.identifier.cristin2169760
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal