Vis enkel innførsel

dc.contributor.authorAntunovic, Biljana
dc.contributor.authorJankovic, Aleksandar
dc.contributor.authorGajic, Darija
dc.contributor.authorAntovic, Nevenka
dc.contributor.authorRasovic, Jelena
dc.contributor.authorCurguz, Zoran
dc.contributor.authorPopovic, Milan
dc.date.accessioned2024-02-29T08:30:07Z
dc.date.available2024-02-29T08:30:07Z
dc.date.created2023-12-08T09:49:11Z
dc.date.issued2023
dc.identifier.citationThermal Science. 2023, OnLine-First Issue 00 252-252.en_US
dc.identifier.issn0354-9836
dc.identifier.urihttps://hdl.handle.net/11250/3120390
dc.description.abstractThe first experimental results of the indoor air quality in two kindergartens located in the Republic of Srpska are presented in this paper. Kindergarten representatives for the year of construction (old and new), building materials, and energy efficiency have been chosen. Indoor air quality measurements (air temperature, relative humidity, ventilation rate, CO2, and radon concentration) were performed during the winter of 2015/2016. Measured indoor air quality parameters are discussed and compared to the international standards BAS EN 16798-1, ASHRAE 62.1, and ISO 7730. The average measured radon concentrations for both buildings have not exceeded the level of 200 Bqm-3, but for reliable results, long-term measurement needs to be performed. The CO2 concentration in the old kindergarten fulfills the BAS EN 16798-1 requirement for category I during 62.43% of total occupancy time, while for the new kindergarten, it is only 5.79% of full occupancy time. Results of CO2 concentration confirm that good sealing of the envelope of new buildings and user behavior (number of users and natural ventilation) does affect air quality. Furthermore, a high correlation between CO2 concentration and relative humidity in both buildings and a more considerable correlation for the new building have been observed.en_US
dc.language.isoengen_US
dc.subjectindoor air quality, kindergarten, temperature, relative humidity, number of air changes, CO2 concentration, radon concentrationen_US
dc.titleThe first test of indoor air quality in kindergartens of the Republic of Srpskaen_US
dc.title.alternativeThe first test of indoor air quality in kindergartens of the Republic of Srpskaen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionpublishedVersionen_US
dc.source.pagenumber252-252en_US
dc.source.volumeOnLine-First Issue 00en_US
dc.source.journalThermal Scienceen_US
dc.identifier.doi10.2298/TSCI230114252A
dc.identifier.cristin2210809
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel