Vis enkel innførsel

dc.contributor.authorØhrn, Frank-David
dc.contributor.authorEngseth, Lars
dc.contributor.authorPripp, Are Hugo
dc.contributor.authorRöhrl, Stephan Maximilian
dc.contributor.authorSchulz, Anselm
dc.date.accessioned2024-01-22T12:06:17Z
dc.date.available2024-01-22T12:06:17Z
dc.date.created2023-11-28T12:53:17Z
dc.date.issued2023
dc.identifier.citationActa Orthopaedica. 2023, 94 550-554.en_US
dc.identifier.issn1745-3674
dc.identifier.urihttps://hdl.handle.net/11250/3113102
dc.description.abstractBackground and purpose: Radiostereometric analysis (RSA) is the gold standard for evaluation of migration of implants. CT-RSA has been shown to have precision at the level of RSA in hip, shoulder, and knee joint replacements. We aimed to assess the impact of dose reduction on precision of CT-RSA on tibial implants, comparing it with previously published data on precision of standard dose CT-RSA on tibial implants. Material and methods: We performed a total knee arthroplasty on a porcine knee cadaver, and subsequent CT-RSA with low effective doses (0.02 mSv). We compared the results with previously published CT-RSA data with standard (0.08 mSv) dose. The primary outcome variable was the difference in precision of the maximum total translation (MTT). Secondary variables included ratios of variances and standard deviations, and precision of peripheral point translations, center-of-mass translations, and rotations. A difference of more than 0.1 mm in precision was defined as clinically relevant. Our hypothesis was that precisions of low and standard CT-RSA doses were equal. Results: Low dose (mean 0.07, 95% confidence interval [CI] 0.06–0.08) and standard dose CT-RSA (0.08, CI 0.07–0.09) achieve similar precision, with difference in precision of MTT of 0.01, CI 0.00–0.02 mm. The F-statistic (0.99, CI 0.63–1.55) and sdtest (1.05, CI 0.43–2.58) also supported this. Conclusion: We conclude that the precision of low dose CT-RSA for tibial implants on a porcine cadaver is equal to standard dose CT-RSA. However, these findings should be confirmed in clinical trials.en_US
dc.language.isoengen_US
dc.publisherMedical Journals Sweden ABen_US
dc.rightsNavngivelse-Ikkekommersiell 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/deed.no*
dc.titleDose reduction does not impact the precision of CT-based RSA in tibial implants: a diagnostic accuracy study on precision in a porcine cadaveren_US
dc.title.alternativeDose reduction does not impact the precision of CT-based RSA in tibial implants: a diagnostic accuracy study on precision in a porcine cadaveren_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.source.pagenumber550-554en_US
dc.source.volume94en_US
dc.source.journalActa Orthopaedicaen_US
dc.identifier.doi10.2340/17453674.2023.24022
dc.identifier.cristin2203792
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse-Ikkekommersiell 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse-Ikkekommersiell 4.0 Internasjonal