Show simple item record

dc.contributor.authorSæbø, Ingvill Pedersen
dc.contributor.authorBjørås, Magnar
dc.contributor.authorFranzyk, Henrik
dc.contributor.authorHelgesen, Emily
dc.contributor.authorBooth, James Alexander
dc.date.accessioned2023-10-25T12:45:55Z
dc.date.available2023-10-25T12:45:55Z
dc.date.created2023-03-01T14:05:19Z
dc.date.issued2023
dc.identifier.citationInternational Journal of Molecular Sciences. 2023, 24 (3), .en_US
dc.identifier.issn1661-6596
dc.identifier.urihttps://hdl.handle.net/11250/3098703
dc.description.abstractIn vitro determination of hemolytic properties is a common and important method for preliminary evaluation of cytotoxicity of chemicals, drugs, or any blood-contacting medical device or material. The method itself is relatively straightforward, however, protocols used in the literature vary substantially. This leads to significant difficulties both in interpreting and in comparing the obtained values. Here, we examine how the different variables used under different experimental setups may affect the outcome of this assay. We find that certain key parameters affect the hemolysis measurements in a critical manner. The hemolytic effect of compounds tested here varied up to fourfold depending on the species of the blood source. The use of different types of detergents used for generating positive control samples (i.e., 100% hemolysis) produced up to 2.7-fold differences in the calculated hemolysis ratios. Furthermore, we find an expected, but substantial, increase in the number of hemolyzed erythrocytes with increasing erythrocyte concentration and with prolonged incubation time, which in turn affects the calculated hemolysis ratios. Based on our findings we propose an optimized protocol in an attempt to standardize future hemolysis studies.en_US
dc.language.isoengen_US
dc.publisherMDPIen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleOptimization of the Hemolysis Assay for the Assessment of Cytotoxicityen_US
dc.title.alternativeOptimization of the Hemolysis Assay for the Assessment of Cytotoxicityen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.source.pagenumber0en_US
dc.source.volume24en_US
dc.source.journalInternational Journal of Molecular Sciencesen_US
dc.source.issue3en_US
dc.identifier.doi10.3390/ijms24032914
dc.identifier.cristin2130500
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal