Vis enkel innførsel

dc.contributor.authorSkirbekk, Fanny
dc.contributor.authorMauseth, Frank
dc.contributor.authorMeyer, Hans Kristian Hygen
dc.date.accessioned2023-03-24T08:43:06Z
dc.date.available2023-03-24T08:43:06Z
dc.date.created2022-12-06T15:45:19Z
dc.date.issued2022
dc.identifier.issn2535-3969
dc.identifier.urihttps://hdl.handle.net/11250/3060249
dc.description.abstractalternatives to the potent greenhouse gas SF6 in medium voltage (MV) gas insulated switchgear. MV products using this gas mixture are already commercially available, but there is still a lack of knowledge about this gas mixture especially regarding pre-breakdown phenomena. In this study, positive and negative streamers are studied in technical air with 7.5 %vol C5-FK at 1.0, 1.3, and 1.5 bar (absolute pressure). Similar tests were done in technical air (80% N2, 20% O2) for comparison with the C5-FK results. The streamers emerged from a grounded needle electrode placed 53mm below a planar electrode. The electrode setup was stressed by a non-standard lightning impulse voltage with voltage peaks varying from 52 to 129 kV. A photomultiplier tube (PMT) was used to register the streamers, and an iCCD camera was used to image the streamers. The pre-breakdown phenomena in C5-FK+air were found to be shorter, less than 1/5 of the length, and to branch less than in pure technical air. The streamer branches in both gas mixtures became wider and less clear when the pressure was decreased. Leader-like channels were observed for C5-FK+air at 1.5 bar (both polarities) and at 1.3 bar (negative streamers).en_US
dc.description.abstractPre-Breakdown Phenomena in Technical Air with and without C5-Fluoroketone for a Rod-Plane Gapen_US
dc.language.isoengen_US
dc.publisherNORD-ISen_US
dc.relation.urihttps://www.ntnu.no/ojs/index.php/nordis/article/view/4553
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titlePre-Breakdown Phenomena in Technical Air with and without C5-Fluoroketone for a Rod-Plane Gapen_US
dc.title.alternativePre-Breakdown Phenomena in Technical Air with and without C5-Fluoroketone for a Rod-Plane Gapen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionpublishedVersionen_US
dc.source.volume27en_US
dc.source.journalProceedings of the Nordic Insulation Symposiumen_US
dc.source.issue1en_US
dc.identifier.doi10.5324/nordis.v27i1.4553
dc.identifier.cristin2089597
dc.relation.projectNorges forskningsråd: 323328en_US
dc.relation.projectNorges forskningsråd: 319930en_US
cristin.ispublishedtrue
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal