Comparison of droop-based grid-forming and PLL-based grid-following control of VSC during symmetrical fault
Master thesis
Date
2022Metadata
Show full item recordCollections
- Institutt for elkraftteknikk [2545]
Abstract
Denne oppgaven handler om kontroll av spenningsomformere under et feilscenario. Merspesifikt så handler oppgaven om sammenligning av to forskjellige kontrollmetoder,droop-basert nettdannende kontroll og faselåst-sløyfe basert nettfølgende kontroll.Feilscenarioene vil bli variert for å bestemme karakteristikken til de to forskjelligekontrollmetodene, og for å kvantifisere fordelene og ulempene ved de. Under simuleringenble det oppdaget vanskeligheter med å begrense feilstrømmene i den nettdannendekontrollmodusen. To enkle måter å begrense feilstrømmene ble funnet ut av, ogsammenlignet med hverandre, samt den nettfølgende kontrollmetoden.Sammenligningen er gjort i et scenario gitt av Siemens Energy - Offshore Marine Center. Dehar felterfaring med droop-basert nettdannende kontrol av spenningsomformere gjennomderes arbeid med å levere kraftsystem og ladesystem til elektriske passasjerferger i Norge.De har opplevd utfordringer knyttet til feilsituasjoner i ytterliggende nett under lading, ogdette vil være bakgrunnen for simuleringene som gjøres i denne oppgaven. Scenarioet ermodellert i Matlab/Simulink, og analysen gjøres i tids-domenet.Hovedforskjellene mellom kontrollmetodenes evne til å håndtere en symmetrisk feil erknyttet til kontrollmålene deres. Den nettdannende spenningsomformeren vil injiserereaktive strømmer til kraftsystemet for å opprettholde spenningsnivået, mens dennettfølgende spenningsomformeren vil tillate spenningen å falle. Feilstrømbegrensningene blegjort gjennom å innføre metningsgrenser på foroverkoblingen i spenningsløkka eller fjerneden totalt. Dette gikk veldig på bekostning av prestasjonen til den nettdannendespenningsomformeren, som gjorde at den nettfølgende spenningsomformeren håndtertefeilsituasjonen betydelig bedre.Den nettdannende spenningsomformeren var mindre robust når det gjaldt økt feiltid, oghadde en lavere kritisk klareringstid sammenlignet med nettfølgende spenningsomformeren.Effekten av økende feilstørrelse, m.a.o feilstrøm, var mindre skadelig enn effekten av øktfeiltid. Den nettfølgende spenningsomformeren sin svakhet ble tydelig da linjeimpedansenble økt, ettersom den er sterkt avhengig av en god forbindelse til det ytterliggende nettet.Det ble derfor konkludert at uten riktige strømbegrensningsmetoder på den droop-basertenettdannende spenningsomformeren, så vil den faselåste-sløyfe-baserte nettfølgendespenningsomformeren prestere bedre utenom i scenarioer med høy linjeimpedanse. This thesis is about controlling of voltage source converters during a fault scenario. Morespecifically it is about comparing two different control methods, namely droop-basedgrid-forming control and PLL-based grid-following control. The fault conditions are variedin order to uncover the performance characteristics of the two control methods and quantifytheir advantages and disadvantages. During the simulation study the difficulty of limitingfault currents in grid-forming control was discovered. Two simple methods of limiting thefault current was discovered, and compared with each other, as well as with thegrid-following control.The comparison was done in a scenario provided by Siemens Energy - Offshore MarineCenter. They have field experience with operation and control of droop-based grid-formingconverters, through their work in delivering power system solutions to electric passengerferries in Norway. Their challenges related to handling of faults in the outer-lying gridduring charging, is the background for the simulation study in this thesis. The scenario wasmodelled in the Matlab/Simulink environment, and the simulation study performed in thetime-domain.The main difference between the control methods ability to handle a symmetrical fault isrelated to their control objectives. The grid-forming converter injects large reactive currentsto prevent the voltage from dropping, whereas the grid-following converter allows the voltageto drop. The fault current limitation was done through saturating or removing thefeed-forward term in the voltage control loop. This came at a large cost of performance forthe grid-forming control, resulting in a superior ability to handle the fault for thegrid-following control.The grid-forming converter had less robustness when it came to varying fault duration, andhad a smaller critical clearing time than compared to the grid-following converter. The effectof increasing the fault magnitude, i.e fault current, was less detrimental than increasing thefault duration. The grid-following converters point of weakness was discovered whenincreasing the line impedance, as it highly dependant on a strong connection to the powergrid. It was therefore concluded that without proper fault current limitations techniques inthe droop-based grid-forming converter, the PLL-based grid-following converter performsbetter whenever not exposed to a high impedance grid