Evaluation of occupant’s adaptive thermal comfort behaviour in naturally ventilated courtyard houses
Peer reviewed, Journal article
Published version
Date
2021Metadata
Show full item recordCollections
Original version
Smart and Sustainable Built Environment. 2021, 11 (4), 793-811. https://doi.org/10.1108/SASBE-02-2021-0020Abstract
Purpose
In vernacular buildings, many climatic and passive solutions have been used to create indoor thermal comfort. Seasonal occupant movement is an example of a traditional response to increasing thermal comfort. This article investigates the influence of these user behaviours on thermal comfort in courtyard houses.
Design/methodology/approach
Parametric models of three different scenarios of courtyard houses are simulated. The courtyard houses are located in Shiraz, Iran, and share the same orientation and construction materials. To enhance the accuracy of the study, the indoor adaptive thermal comfort (ATC) analysis is performed with three different window-to-wall ratios (WWR) of 25, 50 and 75%. The ACT analysis is performed on an hourly basis for summer and winter scenarios.
Findings
The results demonstrate that the indoor ATC is 8.3% higher in winter than in the summer in the seasonal zones. During the summer, the amount of ATC is relatively sustained in all zones. Unlike common beliefs, seasonal movement can enhance the ATC, especially during winter, specifically in the northern part of the courtyard. In northern zones, the seasonal movement of occupants improves the indoor ATC from 10.1 to 23.7%, and in southern zones, the improvement is from 2.2 to 4.8%.
Originality/value
This research presents a new numerical investigation into occupants' seasonal movements in courtyard houses during summer and winter. It provides a precise pattern to show how much this seasonal movement can affect the habitant's ATC.