dc.description.abstractThis study investigated the effect of fire on the ultimate load-bearing capacity of reinforced concrete (RC) slabs. The structural response of RC circular specimens subjected to static load conditions after exposure to a hydrocarbon fire on one side of the specimen was examined. Two fire exposure times were considered (60 and 120 min) in addition to reference non-exposed specimens. The static response was evaluated in the damaged specimens in residual conditions after natural cooling from the elevated temperatures. The temperature distribution across the thickness of the slabs and their load–displacement response was measured. The decrease in the stiffness of the slabs due to the thermal exposure was studied by means of direct ultrasonic pulse velocity (UPV) measurements made before and after the fire tests. The decrease in global stiffness was partially accounted for by UPV measurements. The experimental results showed two peaks in the load-deflection response of the slabs. The first peak was related to an arching mechanism introduced by the specific set-up used. The second peak, corresponding to the ultimate load, occurred due to tensile membrane action at large deflections. While the former was strongly affected by the fire exposure, with the load being halved after the 120-min exposure, the latter was not greatly affected by either the presence of fire or the exposure time. Simplified mechanical models were used to explain the behavior of the RC slabs during the tests.en_US
dc.language.isoengen_US
dc.publisherWileyen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleFailure characteristics of reinforced concrete circular slabs subsequently subjected to fire exposure and static load: An experimental studyen_US
dc.title.alternativeFailure characteristics of reinforced concrete circular slabs subsequently subjected to fire exposure and static load: An experimental studyen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionacceptedVersionen_US
dc.source.journalStructural Concreteen_US
dc.identifier.doihttps://doi.org/10.1002/suco.202200054
dc.identifier.cristin2098574
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal