Vis enkel innførsel

dc.contributor.authorRomano, A.
dc.contributor.authorGrammatikos, S.
dc.contributor.authorRiley, M.
dc.contributor.authorBras, A.
dc.date.accessioned2021-11-04T13:33:13Z
dc.date.available2021-11-04T13:33:13Z
dc.date.created2021-11-01T11:13:26Z
dc.date.issued2021
dc.identifier.issn2352-7102
dc.identifier.urihttps://hdl.handle.net/11250/2827949
dc.description.abstractUnderstanding the relationship that earth-based mortars have with both water and temperature is imperative to optimise moisture buffering properties. Specific Heat Capacity (Cp) is a key factor to understand the benefits in terms of thermal mass and latent heat. This paper presents the results of bio-based earth mortars (with fibres consisting of two varieties of sheep wool: Wool 1 (W1), Wool 2(W2) and Saw Mill Residue (SMR)) stabilised at 53% and 75% Relative Humidity (RH). Differential Scanning Calorimetry (DSC) according to ISO 11357–4 was used to calculate Cp of the aforementioned mortars. The temperature range of this experiment was that of 0–50 °C with a particular focus on values at 20 °C as this best represented a suitable indoor temperature. From these experiments, the results demonstrate that when stabilised at different RH, the difference in Cp was bio-fibre dependant and had a range between 0.71– 1.01 kJ/kg.K at 53% RH and 0.85–1.14 kJ/kg.K at 75% RH. These differences could potentially be attributed to the materials ability to readily accept water molecules. This emphasised that incorporating bio-fibres to a plain mixture (PL) can increase the Cp by up to 60%; significantly improving the thermal inertia of the building material. By reducing this temperature differential, it will reduce the heating requirements of a building which as consequential carbon reduction and thermal comfort benefits. Overall, SMR has the largest Cp for 75% at 20 °C was 1.141 kJ/kg.K, therefore specifically, this fibre would be the most effective to implement within a building. It also demonstrates the differences of the samples adsorption and absorption of water in differing hygrothermal environments.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.titleDetermination of specific heat capacity of bio-fibre earth mortars stabilised at different relative humidities using Differential Scanning Calorimetryen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holderThe published version of the article will not be available due to copyright restrictions by Elsevieren_US
dc.source.journalJournal of Building Engineeringen_US
dc.identifier.doi10.1016/j.jobe.2021.102738
dc.identifier.cristin1950117
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel