Experimental and simulated evaluations of airborne contaminant exposure in a room with a modified localized laminar airflow system

Cheng, Zhu; Aganovic, Amar; Cao, Guangyu; Bu, Zhongming
Peer reviewed, Journal article
Published version
Åpne
Cheng (Låst)
Permanent lenke
https://hdl.handle.net/11250/2827456
Utgivelsesdato
2021
Metadata
Vis full innførsel
Samlinger
  • Institutt for energi og prosessteknikk [4541]
  • Publikasjoner fra CRIStin - NTNU [41955]
Originalversjon
Environmental science and pollution research international. 2021, 28 30642-30663.   10.1007/s11356-021-12685-4
Sammendrag
The traditional mixing ventilation is not an energy effective approach to remove indoor air pollutants, maintain breath zone air quality, and control the airborne transmission. This study investigated the potential of a localized laminar airflow ventilation system to alleviate human exposure to pollutants. Breathing thermal manikins with sitting posture and supine posture were used to simulate the human. N2O was used as the tracer gas to simulate the indoor pollutant emission. The contaminant exposure index (εexp) and intake fraction index (IF) were used to assess the risk of human pollutant exposure for various supply air velocities given different emission source positions. Enhanced pollutant removal efficiency (Eff) (from the result) showed the qualification and desirability of the localized laminar airflow ventilation system in improving the breath zone air quality. The results showed that the CFD results could fit well with the experimental data and found out the interaction between thermal plume and supply air. The results also indicated a low εexp and IF, with over 90%, all of which were highly correlated with the supply velocity. Human’s different breathing methods have little influence on the pollutant exposure so as to the location of the pollution source. This study found that localized laminar airflow ventilation system could efficiently provide fresh air to the breathing zone without sacrificing the thermal environment around human. It can be used for small region air quality control such as that in the bedroom and living room where desired air quality is favored.
Utgiver
Springer
Tidsskrift
Environmental science and pollution research international
Opphavsrett
The published version of the article will not be available due to copyright restrictions by Springer

Kontakt oss | Gi tilbakemelding

Personvernerklæring
DSpace software copyright © 2002-2019  DuraSpace

Levert av  Unit
 

 

Bla i

Hele arkivetDelarkiv og samlingerUtgivelsesdatoForfattereTitlerEmneordDokumenttyperTidsskrifterDenne samlingenUtgivelsesdatoForfattereTitlerEmneordDokumenttyperTidsskrifter

Min side

Logg inn

Statistikk

Besøksstatistikk

Kontakt oss | Gi tilbakemelding

Personvernerklæring
DSpace software copyright © 2002-2019  DuraSpace

Levert av  Unit