Fault diagnosis of downhole drilling incidents using adaptive observers and statistical change detection

Willersrud, Anders; Blanke, Mogens; Imsland, Lars Struen; Pavlov, Alexey
Journal article, Peer reviewed
Thumbnail
View/Open
AW-JPC14.pdf (2.615Mb)
URI
http://hdl.handle.net/11250/280278
Date
2015
Metadata
Show full item record
Collections
  • Institutt for teknisk kybernetikk [2842]
  • Publikasjoner fra CRIStin - NTNU [26648]
Original version
Journal of Process Control 2015   10.1016/j.jprocont.2014.12.010
Abstract
Downhole abnormal incidents during oil and gas drilling cause costly delays, and may also potentially lead to dangerous scenarios. Different incidents will cause changes to different parts of the physics of the process. Estimating the changes in physical parameters, and correlating these with changes expected from various defects, can be used to diagnose faults while in development. This paper shows how estimated friction parameters and flow rates can be used to detect and isolate the type of incident, as well as isolating the position of a defect. Estimates are shown to be subjected to non-Gaussian, $t$-distributed noise, and a dedicated multivariate statistical change detection approach is used that detects and isolates faults by detecting simultaneous changes in estimated parameters and flow rates. The properties of the multivariate diagnosis method are analyzed, and it is shown how detection and false alarm probabilities are assessed and optimized using data-based learning to obtain thresholds for hypothesis testing. Data from a 1400 m horizontal flow loop is used to test the method, and successful diagnosis of the incidents drillstring washout (pipe leakage), lost circulation, gas influx, and drill bit nozzle plugging are demonstrated.
Description
- author preprint
Publisher
Elsevier

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit
 

 

Browse

ArchiveCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsDocument TypesJournalsThis CollectionBy Issue DateAuthorsTitlesSubjectsDocument TypesJournals

My Account

Login

Statistics

View Usage Statistics

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit