Vis enkel innførsel

dc.contributor.authorSabbir, A. S. M. Younus Bhuiyan
dc.contributor.authorSaha, Chayan Kumer
dc.contributor.authorNandi, Rajesh
dc.contributor.authorForid Uz Zaman, Md.
dc.contributor.authorAlam, Md. Monjurul
dc.contributor.authorSarker, Shiplu
dc.date.accessioned2021-10-12T07:37:18Z
dc.date.available2021-10-12T07:37:18Z
dc.date.created2021-10-10T19:21:04Z
dc.date.issued2021
dc.identifier.issn2071-1050
dc.identifier.urihttps://hdl.handle.net/11250/2789138
dc.description.abstractBiogas is produced in Bangladesh mostly through fixed-dome anaerobic digesters, which usually operate without any temperature controller. An experiment was conducted to monitor the seasonal temperature variation inside a fixed-dome type digester and its effect on biogas composition. A commercial-scale digester with a working volume of 350 m3 was used for this study. Three k-type thermocouple sensors were used to monitor the ambient, biogas, and slurry temperatures in real-time. The results showed that the average ambient temperature in the autumn, late autumn, and winter was 29.05, 22.90, and 17.64 °C, respectively. The average slurry temperature in the autumn (30.38 °C) was higher than in the late autumn (29.36 °C) and in the winter (25.76 °C). The highest and lowest slurry temperatures were found to be 31.11 and 24.47 °C, respectively, which indicated that the digester worked within a wide temperature range, establishing both psychrophilic and mesophilic operational conditions. Higher methane concentrations were observed in the autumn than in the late autumn and winter. The CO2 and H2S concentrations were higher in the winter than those of in the autumn and late autumn. The electricity generation in the winter was 47.85% and 45.15% lower than in the autumn and late autumn, respectively.en_US
dc.language.isoengen_US
dc.publisherMDPIen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleEffects of Seasonal Temperature Variation on Slurry Temperature and Biogas Composition of a Commercial Fixed-Dome Anaerobic Digester Used in Bangladeshen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.source.volume13en_US
dc.source.journalSustainabilityen_US
dc.source.issue19en_US
dc.identifier.doihttps://doi.org/10.3390/su131911096
dc.identifier.cristin1944721
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal