Show simple item record

dc.contributor.authorNygård, Håkon Tormodsen
dc.contributor.authorGhirardo, Giulio
dc.contributor.authorWorth, Nicholas
dc.date.accessioned2021-07-27T08:52:35Z
dc.date.available2021-07-27T08:52:35Z
dc.date.created2021-07-26T11:08:16Z
dc.date.issued2021
dc.identifier.citationCombustion and Flame. 2021, 233 111565-?.en_US
dc.identifier.issn0010-2180
dc.identifier.urihttps://hdl.handle.net/11250/2765330
dc.description.abstractIn the current study azimuthal forcing of an annular combustor with swirling flames has been performed to present for the first time the Heat Release Rate (HRR) response to all possible pressure fields of the first azimuthal mode up to a finite amplitude limit. The response is first quantified through the conventional Flame Describing Function (FDF) framework, showing a difference in response which depends on whether the acoustic field rotates anti-clockwise or clockwise, albeit with some scatter. Additionally and somewhat surprisingly, a finite HRR response is observed for flames exactly in the pressure node. An Azimuthal FDF is introduced, based on the decomposition of the spatial HRR response through Bloch theory, to better highlight the difference in HRR response to the anti-clockwise and clockwise components of the acoustic field and reduce scatter. A clear difference in response is observed, with a significantly higher response to the anti-clockwise forcing component compared to the clockwise component, independent of the prescribed pressure mode. The difference is attributed to the systematic symmetry breaking introduced by using an annular enclosure of finite curvature and width with swirling flames. It is argued that the finite curvature and width of the geometry and the swirl need to be both present to observe this effect. The difference in response results in a difference between the nature angle of the HRR mode and that of the acoustic field, explaining the relatively large HRR response observed for flames in the pressure node. The Azimuthal FDF describe all of these phenomena well, and is therefore considered more suitable than the conventional FDF to characterise the response in an annular combustor.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleAzimuthal flame response and symmetry breaking in a forced annular combustoren_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.source.pagenumber111565-?en_US
dc.source.volume233en_US
dc.source.journalCombustion and Flameen_US
dc.identifier.doihttps://doi.org/10.1016/j.combustflame.2021.111565
dc.identifier.cristin1922634
dc.relation.projectEC/H2020/677931en_US
dc.description.localcode© 2021 The Author(s). Published by Elsevier Inc. on behalf of The Combustion Institute. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode2


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal