Vis enkel innførsel

dc.contributor.authorJernelv, Ine Larsen
dc.contributor.authorStrøm, Karina
dc.contributor.authorHjelme, Dag Roar
dc.contributor.authorAksnes, Astrid
dc.date.accessioned2020-03-26T13:52:24Z
dc.date.available2020-03-26T13:52:24Z
dc.date.created2020-02-28T12:58:46Z
dc.date.issued2020
dc.identifier.issn0277-786X
dc.identifier.urihttps://hdl.handle.net/11250/2648911
dc.description.abstractA fiber-coupled transmission spectroscopy setup using a pulsed external-cavity quantum cascade laser (EC-QCL, 1200-900 cm−1 ) has been developed and demonstrated for measurements of aqueous solutions. The system has been characterised with regard to the laser noise and optimal optical pathlength. Solutions with glucose were used to further test the setup, and glucose concentrations down to physiologically relevant levels (0-600 mg/dl) were investigated. Albumin, lactate, urea, and fructose in various concentrations were added as interfering substances as their absorption bands overlap with those of glucose, and because they may be of interest in a clinical setting. Analyte concentrations were predicted using partial least-squares (PLS) regression, and the root-mean-square error of cross-validation for glucose was 10.7 mg/dl. The advantages of using a convolutional neural network (CNN) for regression analysis in comparison to the PLS regression were also shown. The application of a CNN gave an improved prediction error (8.3 mg/dl), and was used to identify important spectral regions. These results are comparable to state-of-the-art enzymatic glucose sensors, and are encouraging for further research on optics-based glucose sensors.en_US
dc.language.isoengen_US
dc.publisherSociety of Photo Optical Instrumentation Engineers (SPIE)en_US
dc.titleMid-infrared spectroscopy with a fiber-coupled tuneable quantum cascade laser for glucose sensingen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.source.journalProceedings of SPIE, the International Society for Optical Engineeringen_US
dc.identifier.doi10.1117/12.2543984
dc.identifier.cristin1798415
dc.description.localcode© 2020 Society of Photo Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.en_US
cristin.unitcode194,63,35,0
cristin.unitnameInstitutt for elektroniske systemer
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel