Vis enkel innførsel

dc.contributor.authorPopko, Wojciech
dc.contributor.authorRobertson, Amy
dc.contributor.authorJonkman, Jason
dc.contributor.authorWendt, Fabian
dc.contributor.authorThomas, Philipp
dc.contributor.authorMüller, Kolja
dc.contributor.authorKretschmer, Matthias L.
dc.contributor.authorHagen, Torbjørn Ruud
dc.contributor.authorGalinos, Christos
dc.contributor.authorDreff, Jean-Baptiste Le
dc.contributor.authorGilbert, Philippe
dc.contributor.authorAuriac, Bertrand
dc.contributor.authorOh, Sho
dc.contributor.authorQvist, Jacob
dc.contributor.authorSørum, Stian Høegh
dc.contributor.authorSuja, Loup
dc.contributor.authorShin, Hyunkyoung
dc.contributor.authorMolins, Climent
dc.contributor.authorTrubat, Pau
dc.contributor.authorBonnet, Paul
dc.contributor.authorBergua, Roger
dc.contributor.authorWang, Kai
dc.contributor.authorFu, Pengcheng
dc.contributor.authorCai, Jifeng
dc.contributor.authorCai, Zhisong
dc.contributor.authorAlexandre, Armando
dc.contributor.authorHarries, Robert
dc.date.accessioned2020-02-05T12:49:54Z
dc.date.available2020-02-05T12:49:54Z
dc.date.created2020-01-20T16:08:07Z
dc.date.issued2019
dc.identifier.isbn978-0-7918-5889-9
dc.identifier.urihttp://hdl.handle.net/11250/2639840
dc.description.abstractThe main objective of the Offshore Code Comparison Collaboration Continuation, with Correlation (OC5) project is validation of aero-hydro-servo-elastic simulation tools for offshore wind turbines (OWTs) through comparison of simulated results to the response data of physical systems. Phase III of the OC5 project validates OWT models against the measurements recorded on a Senvion 5M wind turbine supported by the OWEC Quattropod from the alpha ventus offshore wind farm. The following operating conditions of the wind turbine were chosen for the validation: (1) Idling below the cut-in wind speed; (2) Rotor-nacelle assembly (RNA) rotation maneuver below the cut-in wind speed; (3) Power production below and above the rated wind speed; and (4) Shutdown. A number of validation load cases were defined based on these operating conditions. The following measurements were used for validation: (1) Strains and accelerations recorded on the support structure; (2) Pitch, yaw, and azimuth angles, generator speed, and electrical power recorded from the RNA. Strains were not directly available from the majority of the OWT simulation tools. Therefore, strains were calculated based on out-of-plane bending moments, axial forces, and cross-sectional properties of the structural members. Also, a number of issues arose during the validation: (1) The need for a thorough quality check of sensor measurements; (2) The sensitivity of the turbine loads to the controller and airfoil properties, which were only approximated in the modeling approach; (3) The importance of estimating and applying an appropriate damping value for the structure; and (4) The importance of wind characteristics beyond turbulence on the loads. The simulation results and measurements were compared in terms of time series, discrete Fourier transforms, power spectral densities, probability density functions of strains and accelerometers. A good match was achieved between the measurements and models set up by OC5 Phase III participants.nb_NO
dc.language.isoengnb_NO
dc.publisherASMEnb_NO
dc.relation.ispartofASME 2019 38th International Conference on Ocean, Offshore and Arctic Engineering. Volume 10: Ocean Renewable Energy
dc.titleValidation of Numerical Models of the Offshore Wind Turbine From the Alpha Ventus Wind Farm Against Full-Scale Measurements Within OC5 Phase IIInb_NO
dc.typeChapternb_NO
dc.description.versionpublishedVersionnb_NO
dc.identifier.doihttps://doi.org/10.1115/OMAE2019-95429
dc.identifier.cristin1778265
dc.relation.projectNorges forskningsråd: 223254nb_NO
dc.description.localcodeCopyright © 2019 by ASMEnb_NO
cristin.unitcode194,64,20,0
cristin.unitnameInstitutt for marin teknikk
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1