dc.description.abstract | Recent development in the energy sector in Norway has made district heating increasingly relevant. In particular, the increased demand for electric power, has contributed to make district heating more important.
A well known problem in district heating, is operational optimization. In this thesis, the problem is investigated on the basis of the Fortum Oslo Varme s system, which consists of more than 40 boilers. All data used in the thesis is gathered from Fortum s data system.
Another prominent theme in district heating, is the possibility for building thermal energy
storages. Methods which can calculate the profitability of investing in thermal energy storages are necessary.
To solve the issue of operational optimization, models for predicting future heat load demand
are necessary. Two such models were developed, the best of which were able to predict the heat load demand with an average error of 7.6% in the years 2013 and 2014.
Additionally, a model for operational optimization was developed. It can be run both with
and without an accumulator tank, so that the operational cost can be compared, and investment
decisions can be taken. It was found that a system with an accumulator tank can save 1.3 million NOK yearly, based on simulations performed on data from 2016. The investment in a tank is not profitable, given an assumed cost of 39 million NOK.
It must, however, be taken into account that potential savings will vary between years. The
simulations also build on some assumptions about the district heating system, and the thermal
energy storage. Since the optimization model is based on randomness, two consecutive
runs would not give the same result. Therefore, additional simulations are required to verify the results. | en |