Vis enkel innførsel

dc.contributor.authorBohloli, Bahman
dc.contributor.authorSkjølsvold, Ola
dc.contributor.authorJustnes, Harald
dc.contributor.authorOlsson, Roger
dc.contributor.authorGrøv, Eivind
dc.contributor.authorAarset, Arnstein
dc.date.accessioned2019-09-10T07:37:40Z
dc.date.available2019-09-10T07:37:40Z
dc.date.created2019-07-01T14:57:22Z
dc.date.issued2019
dc.identifier.issn0886-7798
dc.identifier.urihttp://hdl.handle.net/11250/2614386
dc.description.abstractThis paper presents work being carried out in Work Package 3 of TIGHT (True Improvement in Grouting High pressure Technology for tunnelling) project. The objective is to investigate flow and mechanical properties of three cements (A, B and C) at actual tunnel- and room –temperatures using various laboratory methods. The cements were first characterized in terms of grain size distribution and specific surface area. Then the grouts made from the three cements were tested for flow properties and mechanical strength. Cement grouts were prepared at two different temperatures of 8 °C and 20 °C to represent the actual tunnelling temperature of projects in Scandinavia and the room temperature, respectively. The experimental program comprised of a total of 590 tests, including the tests presented in this paper and elsewhere. The experiments include grain size distribution, specific surface area, viscosity, bleeding, hydration temperature, setting time and strength of cured grout specimens. Four different water to cement (w/c) ratios of 0.6, 0.8, 1.0 and 1.2 were used for most of the tests. Results showed that the grouts prepared from the three cements had quite different behaviour in terms of rheology, flow and mechanical properties. Viscosity of various types of cement grouts is very different at low w/c ratios but the difference decreases with increasing w/c ratio. All three cements fulfil the requirements described by ASTM for bleeding at w/c ratios up to 1.0, but only cement A qualifies for w/c ratios of greater than 1.0. Also cement A sets much faster than cement B and C, as proved by the Vicat needle test and heat of hydration. Temperature evolvement and heat of hydration, during initial stages of setting, is both higher and faster for cement A than cements B and C. Results show that there is a negative correlation between the heat of hydration and the uniaxial compressive strength of cement grout specimens. It is also illustrated that fast temperature increase in a cement grout leads to a lower strength of the cured grout specimen.nb_NO
dc.language.isoengnb_NO
dc.publisherElseviernb_NO
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleCements for tunnel grouting – Rheology and flow properties tested at different temperaturesnb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.source.volume91nb_NO
dc.source.journalTunnelling and Underground Space Technologynb_NO
dc.identifier.doi10.1016/j.tust.2019.103011
dc.identifier.cristin1709090
dc.relation.projectNorges forskningsråd: 236676nb_NO
dc.description.localcode© 2019 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/BY/4.0/).nb_NO
cristin.unitcode194,64,90,0
cristin.unitnameInstitutt for geovitenskap og petroleum
cristin.ispublishedtrue
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal