dc.contributor.author | Mazzanti, Giovanni | |
dc.contributor.author | Castellon, Jerome | |
dc.contributor.author | Chen, George | |
dc.contributor.author | Fothergill, John | |
dc.contributor.author | Fu, M | |
dc.contributor.author | Hozumi, Naohiro | |
dc.contributor.author | Lee, J.H. | |
dc.contributor.author | Li, Jianying | |
dc.contributor.author | Marzinotto, Massimo | |
dc.contributor.author | Mauseth, Frank | |
dc.contributor.author | Morshuis, Peter | |
dc.contributor.author | Reed, Clive | |
dc.contributor.author | Troia, Ivan | |
dc.contributor.author | Tzimas, Antonios | |
dc.contributor.author | Wu, K. | |
dc.date.accessioned | 2019-06-05T06:47:04Z | |
dc.date.available | 2019-06-05T06:47:04Z | |
dc.date.created | 2019-05-30T12:56:01Z | |
dc.date.issued | 2019 | |
dc.identifier.citation | IEEE transactions on dielectrics and electrical insulation. 2019, 26 (3), 973-980. | nb_NO |
dc.identifier.issn | 1070-9878 | |
dc.identifier.uri | http://hdl.handle.net/11250/2599945 | |
dc.description.abstract | The review of materials, design and testing of joints for HVDC extruded cable systems provided in previous Part 1 paved the way to this Part 2 position paper by the DEIS HVDC Cable Systems Technical Committee, whose aim is to remedy the scarcity of existing standardized tests on joints. After a sound analysis, here routine tests are identified as the first practical target for the onset of new testing procedures, AC-PD measurements as the readily-available measurement from manufacturers' experience for quality control of joints during routine tests and VHF/UHF wireless sensors as the best tool for such measurements in the noisy environment of factories. Thereby, a novel protocol for PD measurement using AC voltages and VHF/UHF electromagnetic sensors, for quality control during routine tests on HVDC extruded joints, is proposed. | nb_NO |
dc.description.abstract | The insulation of HVDC extruded cable system joints. Part 2: Proposal of a new AC voltage PD measurement protocol for quality control during routine tests | nb_NO |
dc.language.iso | eng | nb_NO |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | nb_NO |
dc.title | The insulation of HVDC extruded cable system joints. Part 2: Proposal of a new AC voltage PD measurement protocol for quality control during routine tests | nb_NO |
dc.type | Journal article | nb_NO |
dc.type | Peer reviewed | nb_NO |
dc.description.version | acceptedVersion | nb_NO |
dc.source.pagenumber | 973-980 | nb_NO |
dc.source.volume | 26 | nb_NO |
dc.source.journal | IEEE transactions on dielectrics and electrical insulation | nb_NO |
dc.source.issue | 3 | nb_NO |
dc.identifier.doi | 10.1109/TDEI.2019.8726047 | |
dc.identifier.cristin | 1701567 | |
dc.description.localcode | © 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. | nb_NO |
cristin.unitcode | 194,63,20,0 | |
cristin.unitname | Institutt for elkraftteknikk | |
cristin.ispublished | true | |
cristin.fulltext | postprint | |
cristin.qualitycode | 2 | |