Vis enkel innførsel

dc.contributor.authorWang, Congcong
dc.contributor.authorAlaya Cheikh, Faouzi
dc.contributor.authorKaaniche, Mounir
dc.contributor.authorElle, Ole Jacob
dc.date.accessioned2019-02-21T14:01:41Z
dc.date.available2019-02-21T14:01:41Z
dc.date.created2018-10-03T12:22:40Z
dc.date.issued2018
dc.identifier.citationProgress in Biomedical Optics and Imaging. 2018, 1057:105762H6 1-8.nb_NO
dc.identifier.issn1605-7422
dc.identifier.urihttp://hdl.handle.net/11250/2586829
dc.description.abstractIn image guided surgery, stereo laparoscopes have been introduced to provide a 3D view of the organs during the laparoscopic intervention. This stereo video could possibly be used for other purposes other than simple viewing: such as depth estimation, 3D rendering of the scene and 3D organ modeling. This paper aims at reconstructing 3D liver surface based on stereo vision technique. The estimated surface of the liver can later be used for registration to preoperative 3D model constructed from MRI/CT scans. For this purpose, we resort to a variational disparity estimation technique by minimizing a global energy function over the entire image. More precisely, based on the gray level and gradient constancy assumptions, a data term and a local as well as a nonlocal smoothness terms are defined to build the cost function. The latter is minimized, by using an appropriate optimization technique, to estimate the disparity map. In order to reduce the disparity search range and the influence of noise, the global variational approach is performed on the coarsest level of the multi-resolution pyramidal representation of the stereo images. Then the obtained low-resolution disparity map is up-sampled with a modified joint bilateral filtering method to the original scale. In vivo liver datasets with ground truth is difficult to obtain, so the proposed method is evaluated quantitatively on two cardiac phantom datasets from Hamlyn Center achieving an accuracy of about 2.2 mm for heart1 and 2.1 mm for heart2. Reconstructed points up to 97% for heart1 and 100% for heart2 are obtained. Qualitative validation on in vivo porcine procedure's liver datasets has shown that our proposed method can estimate the untextured surfaces geometry well.nb_NO
dc.language.isoengnb_NO
dc.publisherSociety of Photo Optical Instrumentation Engineers (SPIE)nb_NO
dc.titleLiver surface reconstruction for image guided surgerynb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.source.pagenumber1-8nb_NO
dc.source.volume1057:105762H6nb_NO
dc.source.journalProgress in Biomedical Optics and Imagingnb_NO
dc.identifier.doi10.1117/12.2297398
dc.identifier.cristin1617556
dc.relation.projectNorges forskningsråd: 247689nb_NO
dc.description.localcode© 2018 Society of Photo Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.nb_NO
cristin.unitcode194,63,10,0
cristin.unitnameInstitutt for datateknologi og informatikk
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.fulltextpreprint
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel