Vis enkel innførsel

dc.contributor.authorOsadebey, Michael
dc.contributor.authorPedersen, Marius
dc.contributor.authorArnold, Douglas
dc.contributor.authorWendel-Mitoraj, Katrina
dc.contributor.authorAlzheimer’s Disease Neuroi, the
dc.date.accessioned2019-01-28T07:57:25Z
dc.date.available2019-01-28T07:57:25Z
dc.date.created2018-08-15T07:59:42Z
dc.date.issued2018
dc.identifier.issn1471-2342
dc.identifier.urihttp://hdl.handle.net/11250/2582490
dc.description.abstractBackground Multi-site neuroimaging offer several benefits and poses tough challenges in the drug development process. Although MRI protocol and clinical guidelines developed to address these challenges recommend the use of good quality images, reliable assessment of image quality is hampered by the several shortcomings of existing techniques. Methods Given a test image two feature images are extracted. They are grayscale and contrast feature images. Four binary images are generated by setting four different global thresholds on the feature images. Image quality is predicted by measuring the structural similarity between appropriate pairs of binary images. The lower and upper limits of the quality index are 0 and 1. Quality prediction is based on four quality attributes; luminance contrast, texture, texture contrast and lightness. Results Performance evaluation on test data from three multi-site clinical trials show good objective quality evaluation across MRI sequences, levels of distortion and quality attributes. Correlation with subjective evaluation by human observers is ≥ 0.6. Conclusion The results are promising for the evaluation of MRI protocols, specifically the standardization of quality index, designed to overcome the challenges encountered in multi-site clinical trials.nb_NO
dc.language.isoengnb_NO
dc.publisherBMC (part of Springer Nature)nb_NO
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleStandardized Quality Metric System for Structural Brain Magnetic Resonance Images in Multi-Center Neuroimaging Studynb_NO
dc.title.alternativeStandardized Quality Metric System for Structural Brain Magnetic Resonance Images in Multi-Center Neuroimaging Studynb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.source.volume18nb_NO
dc.source.journalBMC Medical Imagingnb_NO
dc.source.issue31nb_NO
dc.identifier.doi10.1186/s12880-018-0266-4
dc.identifier.cristin1602075
dc.relation.projectNorges forskningsråd: 247689nb_NO
dc.description.localcode© The Author(s). 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/)nb_NO
cristin.unitcode194,63,10,0
cristin.unitnameInstitutt for datateknologi og informatikk
cristin.ispublishedfalse
cristin.fulltextpreprint
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal