Coping with Harmonics in Smart Grid: variable speed driveswith Back-to-Back Voltage Source Converter versus the matrix converter

Ali, Imran
Master thesis
Thumbnail
View/Open
653087_FULLTEXT01.pdf (1.762Mb)
653087_COVER01.pdf (184.2Kb)
URI
http://hdl.handle.net/11250/257660
Date
2013
Metadata
Show full item record
Collections
  • Institutt for elkraftteknikk [2667]
Abstract
In this master thesis it has been investigated to utilize the matrix as a shunt active power filter and an adjustable speed drive and then compare the matrix converter with the Back-to-Back voltage source converter in terms of active filtering capability and reactive power compensation.In first steps to utilize the matrix converter as a motor drive and a shunt active power filter the control systems for the Permanent magnet synchronous machine, shunt active power filter and 3-phase LC-filter are built. In second steps the simulation result of the matrix converter as motor drive and shunt active power filter is compared with the Back-to-Back voltage source converter in terms of active filtering. The simulation results show that the matrix converter can operate as motor drive very well, but it cannot operate as a shunt active power filter at the same time. In other words it does not have the capability to compensate the harmonic current of the nonlinear load and to make the source current sinusoidal and harmonic free.Whereas the simulation results for Back-to-Back voltage source converter shows that, it can operate as motor drive and a shunt active power filter at the same time. In other word Back-to-Back converter has a good capability for the harmonic current and reactive power compensation.From the simulation results it can be concluded that the Back-to-Back voltage source converter is the best in terms of active filtering capability and reactive power compensation.
Publisher
Institutt for elkraftteknikk

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit
 

 

Browse

ArchiveCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsDocument TypesJournalsThis CollectionBy Issue DateAuthorsTitlesSubjectsDocument TypesJournals

My Account

Login

Statistics

View Usage Statistics

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit