dc.description.abstractThis paper investigates the applicability of real-time hybrid model testing (ReaTHM testing) to the study of offshore systems in deep water. The focus is in particular on slender marine structures connecting floating structures to the seabed, and on how they could be truncated so that a model test setup at a reasonable scale could fit existing hydrodynamic laboratory infrastructures. In this context, ReaTHM testing consists in “substructuring” the slender structures in two parts. At the lower part of the water column, the first substructure is numerical, simulated using a nonlinear finite element method. On the upper part of the water column, the other substructure is physically modelled in an ocean basin. Both substructures interact in real-time through a set of sensors and actuators. This paper addresses through a case study the important issue of accuracy of ReaTHM testing, that is how the behavior of the substructured system varies from that of the emulated system. A top-tensioned riser in 1200m water depth is considered, with two truncation locations: 240m and 600m below the free surface. It is assumed that an artefact is introduced by the ReaTHM test setup, namely a time delay induced by e.g. the numerical calculations, or the actuation system. It is first shown how this artefact influences the accuracy of the setup, and then how the truncation ratio influences the tolerance of the ReaTHM test setup to such an artefact.nb_NO
dc.language.isoengnb_NO
dc.publisherAmerican Society of Mechanical Engineers (ASME)nb_NO
dc.relation.ispartofASME 2017 36th International Conference on Ocean, Offshore and Arctic Engineering - Volume 2: Prof. Carl Martin Larsen and Dr. Owen Oakley Honoring Symposia on CFD and VIV
dc.titleOMAE2017-62498 Real-Time Hybrid Model Testing of a Top Tensioned Riser: a Numerical Case Study on Interface Time-Delays and Truncation Rationb_NO
dc.typeChapternb_NO
dc.typePeer reviewednb_NO
dc.description.versionacceptedVersionnb_NO
dc.identifier.doi10.1115/OMAE2017-62498
dc.identifier.cristin1503606
dc.relation.projectNorges forskningsråd: 254845nb_NO
dc.description.localcodeThis chapter will not be available due to copyright restrictions (c) 2017 by ASMEnb_NO
cristin.unitcode194,64,80,0
cristin.unitcode194,64,20,0
cristin.unitnameSenter for autonome marine operasjoner og systemer
cristin.unitnameInstitutt for marin teknikk
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record