Resolving the Limb Position Effect in Myoelectric Pattern Recognition

Fougner, Anders Lyngvi; Scheme, Erik; Chan, Adrian D. C.; Englehart, Kevin; Stavdahl, Øyvind
Journal article, Peer reviewed
Thumbnail
View/Open
20110727 - Resolving the Limb Position Effect in Myoelectric Pattern Recognition TNSRE-2011-00010.R2 - FINAL SUBMISSION - figures embedded PNG.pdf (1.054Mb)
URI
http://hdl.handle.net/11250/2392260
Date
2011
Metadata
Show full item record
Collections
  • Institutt for teknisk kybernetikk [2252]
  • Publikasjoner fra CRIStin - NTNU [21058]
Original version
IEEE transactions on neural systems and rehabilitation engineering 2011, 19(6):644-651   10.1109/TNSRE.2011.2163529
Abstract
Reported studies on pattern recognition of electromyograms (EMG) for the control of prosthetic devices traditionally focus on classification accuracy of signals recorded in a laboratory. The difference between the constrained nature in which such data are often collected and the unpredictable nature of prosthetic use is an example of the semantic gap between research findings and a viable clinical implementation.

In this work, we demonstrate that the variations in limb position associated with normal use can have a substantial impact on the robustness of EMG pattern recognition, as illustrated by an increase in average classification error from 3.8% to 18%.

We propose to solve this problem by (1) collecting EMG data and training the classifier in multiple limb positions and by (2) measuring the limb position with accelerometers. Applying these two methods to data from ten normally limbed subjects, we reduce the average classification error from 18% to 5.7% and 5.0%, respectively.

Our study shows how sensor fusion (using EMG and accelerometers) may be an efficient method to mitigate the effect of limb position and improve classification accuracy.
Publisher
IEEE
Journal
IEEE transactions on neural systems and rehabilitation engineering

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit
 

 

Browse

ArchiveCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsDocument TypesJournalsThis CollectionBy Issue DateAuthorsTitlesSubjectsDocument TypesJournals

My Account

Login

Statistics

View Usage Statistics

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit