Vis enkel innførsel

dc.contributor.advisorNielsen, Torbjørn Kristiannb_NO
dc.contributor.authorHveem, Øystein Snb_NO
dc.date.accessioned2014-12-19T11:51:31Z
dc.date.available2014-12-19T11:51:31Z
dc.date.created2013-12-03nb_NO
dc.date.issued2013nb_NO
dc.identifier675476nb_NO
dc.identifierntnudaim:10271nb_NO
dc.identifier.urihttp://hdl.handle.net/11250/235389
dc.description.abstractIn this master thesis, an experimental setup for a stand-alone power system has been installed and tested in the Waterpower Laboratory at NTNU. The experimental test rig consisted of a cross-flow turbine, a synchronous generator and an electronic load controller (ELC) manufactured by Remote HydroLight in Afghanistan. The objective of the experiments was to evaluate the performance of the ELC regarding step response in frequency and generator voltage. The controller used phase angle regulation and triacs to divert excess energy to dump loads. The dump loads were heating elements installed and submerged in the lower reservoir in the laboratory. A similar configuration was installed for varying the user load in the energy system. Several tests were performed to evaluate the performance of the ELC. A weak component in the test rig was the transmission system that started to slip. This resulted in an increase in turbine speed during the experiment and reduced the quality of the results. However, the tests indicated that a rapid single peak appears during abrupt disconnection and connection of loads. This may disturb and damage sensitive electronic equipment. Despite this, the ELC performed well during the diffent tests with stable regulation in voltage and frequency.Introducing pulse width modulation would eliminate the unfavorable influence of the triacs in the generator voltage signal. With this modification it is possible to increase the flexibility in the energy system by introducing inductive or conductive loads like a battery bank.A hybrid stand alone energy system connecting existing test rig with a photovoltaic-module has been developed. For a larger and more complex energy system, a more sophisticated system has been designed. Both systems are based on a common DC-grid and charging of a battery bank. This results in a more flexible, reliable and a more stable energy system.nb_NO
dc.languageengnb_NO
dc.publisherInstitutt for energi- og prosessteknikknb_NO
dc.titleTesting av regulator for små turbinernb_NO
dc.typeMaster thesisnb_NO
dc.source.pagenumber156nb_NO
dc.contributor.departmentNorges teknisk-naturvitenskapelige universitet, Fakultet for ingeniørvitenskap og teknologi, Institutt for energi- og prosessteknikknb_NO


Tilhørende fil(er)

Thumbnail
Thumbnail
Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel