Show simple item record

dc.contributor.advisorDeng, Liyuan
dc.contributor.authorHuang, Huang
dc.date.accessioned2015-10-12T14:00:14Z
dc.date.available2015-10-12T14:00:14Z
dc.date.created2015-07-07
dc.date.issued2015
dc.identifierntnudaim:12660
dc.identifier.urihttp://hdl.handle.net/11250/2354130
dc.description.abstractThe parameter of density, viscosity are tested and fitted with the result of solubility measurement. With series of experiments, this chemical blend is considered with a good effect. The mixture of 50% tetrabutylphosphonium glycine with 50% polyethylene glycol (molecular weight: 400) is the suggested blend, and the most suitable temperature is absorption in 120C and desorption in 60C. But the solubility reduced rapidly from the second cycle of experiment, thus recycled use is not recommended.
dc.languageeng
dc.publisherNTNU
dc.subjectChemical Engineering
dc.titleExperimental Study of CO2 Solubility in Ionic Liquids and Polyethylene Glycols
dc.typeMaster thesis
dc.source.pagenumber81


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record