Blar i NTNU Open på forfatter "Mauseth, Frank"
-
High voltage insulation design of coreless, planar PCB transformers for multi-MHz power supplies
Spro, Ole Christian; Mauseth, Frank; Peftitsis, Dimosthenis (Peer reviewed; Journal article, 2021)This paper investigates the insulation design for printed, planar, coreless, and high-frequency transformers with high isolation-voltage. By using finite element analysis on 2D axial-symmetry, the transformer circuit ... -
High Voltage Subsea Connectors for Offshore Wind – Study of Interfaces
Birkeland, Egil Bergstøl (Master thesis, 2023)Europakommisjonen har satt som mål å nå 450 GW med offshore vindparker innen 2050, og med det bli det første karbonnøytrale kontinentet. Det er nødvendig å utvikle teknologi for å redusere kostnaden av flytende vindparker ... -
HVDC-kabelisolasjon for neste generasjons transmisjonsnett
Engebrethsen, Marius (Master thesis, 2010)HVDC-kabler har lenge vært viktige innen energiinfrastrukturen ettersom de kan transportere store mengder energi over store avstander med langt mindre tap enn AC-kabler. HVDC-kabler har tradisjonelt hatt et masseimpregnert ... -
Ikke-desktruktiv tilstandskontroll av kabelskjøter i distribusjonsnett
Hammervoll, Knut Dahle (Master thesis, 2010)En stor andel av distribusjonsnettet verden over begynner å nå, eller allerede har passert, sin tekniske levetid. I Nord-Amerika er over 20 % av kabelanleggene i distribusjonsnettet (mellomspenningsnettet) eldre enn sin ... -
Impuls holdfasthet til polymerfolier ved påkjenning av DC-spenning med overlagret lynimpuls
Olsen, Espen Torlei (Master thesis, 2022)Polymerkabler har i lang tid vært brukt ved HVAC-energidistribusjon. Særlig XLPE har vært et foretrukket valg av isolasjonsmateriale siden det har gode elektriske og mekaniske kvaliteter, er pålitelig og har lave ... -
Influence of HVDC with Overlaid Transients on the Life Time of Wet XLPE Cable Insulation
Hersleth, Halvor Hoen (Master thesis, 2013)There are many technological challenges related to the production of electrical power from offshore wind farms. Norwegian companies are working on different aspects of offshore wind power generation and the Norwegian ... -
Influence of Surface Roughness on Breakdown in Air Gaps at Atmospheric Pressure under Lightning Impulse
Feet, Odd Christian; Mauseth, Frank; Niayesh, Kaveh (Chapter, 2018)In high voltage equipment, gases are often used as insulation material. Several parameters can influence the dielectric withstand voltage of gaseous insulation systems, such as the degree of inhomogeneity, gas pressure and ... -
Innvirkning av fuktighet på dielektriske tap og risiko for partielle utladninger i innstøpte endeviklinger
Bere, Eivind Fosse (Master thesis, 2014)Idag er elektrisk fremdrift på skip der motoren blir forsynt med elektrisitet fra gassturbiner eller dieselmotorer vanlig, og slike system finnes i forskjellige størrelser og konfigurasjoner. En kategori propellsystemer ... -
Innvirkning av HVDC-komponent med overlagrede transienter på vanntrevekst i PEX-isolasjon
Lind, Andreas (Master thesis, 2012)Produksjon av elektrisk kraft fra offshore vindparker vil trolig bli en stor utfordring i fremtiden. Norges forskningsråd har i den forbindelse tilfelt SINTEF Energi femårsprosjektet; «High Voltage AC and DC Subsea Cables ... -
Interfacial Breakdown between Dielectric Surfaces Determined by Gas Discharge
Kantar, Emre; Mauseth, Frank; Ildstad, Erling; Hvidsten, Sverre (Chapter, 2017)This paper examines the influence of the elastic modulus and applied contact pressure on the tangential AC breakdown strength (BDS) of polymer solid-solid interfaces theoretically and experimentally. In the experiments, ... -
Internal Partial Discharges at High DC Voltage and the Effect of Superimposed AC Voltage
Olsen, Pål Keim (Doctoral theses at NTNU;2020:327, Doctoral thesis, 2020)The power electronic equipment needed in HVDC grids produces an AC ripple voltage with amplitude of around one-hundredth of the main DC voltage. The high voltage can result in partial discharges (PDs), which are a sign of ... -
Investigation of Electrical Properties of a new low-GWP Insulation Gas - Comparison of AirPlus and Synthetic Air
Mong, Ruben (Master thesis, 2018)Sulfur hexafluoride (SF6) is a widely used insulation gas in medium- to high-voltage equipment due to its excellent dielectric properties. It has however one important weakness; a large global warming potential (GWP) of ... -
Karakterisering av silikongummi for HVDC subsea-konnektorer
Mørk, Vemund Kaurstad (Master thesis, 2016)En subseakonnektor brukes til å koble sjøkabler sammen med elektrisk utstyr på havbunnen. En viktig komponent i subseakonnektoren er membranen som skal svipe av vann fra kontakten ved tilkobling til konnektoren. Et egnet ... -
Kvalitetssikring av polymerisolerte HVDC kabler ved hjelp av spenningsprøving
Ytterstad, Marit Holbø (Master thesis, 2008)Kvalitetssikring av polymerisolerte HVDC kabler ved hjelp av spenningsprøving -
Lifetime Estimation of Extruded HVDC Cable Insulation
Gerhard, Silas Merlin (Master thesis, 2024)Ekstruderte HVDC-kabler er et nøkkelprodukt for global og bærekraftig elektrifisering. Derfor utføres det HVDC-nedbrytningstester på kabelskall for å estimere levetiden til DC-XLPE-kabelisolasjonen. I tillegg utføres det ... -
Lightning Impulse Testing in Short Air-Gaps and Memory Effect of Previous Discharges
Subhana, Arik; Støa-Aanensen, Nina Sasaki; Gammelsæter, Marte; Marskar, Robert; Mauseth, Frank (Peer reviewed; Journal article, 2024)This paper reports on an observed phenomenon of increasing breakdown voltage while performing standard up and down lightning impulse (LI) testing in short air-gaps with weakly non-uniform field in an enclosed volume. The ... -
Longitudinal AC Breakdown Voltage of XLPE-XLPE Interfaces Considering Surface Roughness and Pressure
Kantar, Emre; Hvidsten, Sverre; Mauseth, Frank; Ildstad, Erling (Journal article; Peer reviewed, 2017)The interfacial breakdown between two dielectric surfaces has been reported to represent one of the principal causes of failure for power cable joints and connectors; thus, a better understanding of interfacial breakdown ... -
Multiple barrierer i inhomogene luftgap ved lynoverspenninger
Solbakken, Jan-Henrik (Master thesis, 2013)Føremålet med dei utførte forsøka i denne masteroppgåva er å kunna føresjå og forklara endringar i haldfastheita når multiple barrierar er nytta som isolasjon i eit stang-plate-gap.Forsøka vart utført med positiv ... -
New Environmentally-friendly Insulation Gases: Breakdown Mechanisms along Insulating Cylinders when implementing Barriers and Triple Junction Gaskets
Osberg, Helene Grimstad (Master thesis, 2023)SF6 er en kraftig drivhusgass, som benyttes i mellomspennings gasisolerte koblingsanlegg. Det er sannsynlig at SF6 kommer til å bli strengere regulert i fremtiden. Nye miljøvennlige isolasjonsajonsgasser, som trykksatt ... -
New Environmentally-friendly Insulation Gases: Pre-breakdown and Breakdown Mechanisms near Insulating Surfaces under Fast Voltage Impulses
Nessa, Stian (Master thesis, 2022)Med det nåværende presset for å fase ut SF6, er det nødvendig med nye design av høyspentutstyr for å minimere konsekvensene av overgangen til mer miljøvennlige isolasjonsgasser. For å oppnå dette kreves en dypere forståelse ...