Akustikk i studentboliger

Garli, Odin; Malaky, Malek
Bachelor thesis
Thumbnail
View/Open
no.ntnu:inspera:300974106:356937086.pdf (13.30Mb)
URI
https://hdl.handle.net/11250/3204784
Date
2025
Metadata
Show full item record
Collections
  • Institutt for vareproduksjon og byggteknikk [1194]
Abstract
I denne oppgaven har vi målt og testet to forskjellige bygg med studentboliger, for å kunne vurdere byggets egenskaper opp mot kravene som er satt i teknisk forskrift. Vi har målt verdiene vertikalt over etasjeskiller for å kunne vurdere lyden som slipper igjennom etasjeskiller i byggene. Kravet som ble satt for oppgaven var at det skulle tas utgangspunkt i etasjeskiller og at det skulle være en tre-basert etasjeskiller.

Formålet med oppgaven var å lære seg bruken av måleinstrumentene, for akustikkmålinger samt vurdere hvordan studentboligene i området var, med tanke på kravene satt i teknisk forskrift for akustikk. Det ene bygget vi målte fikk vi vite at det hadde vært en del klager fra beboere på støy og derfor var det et interessant bygg å måle for å se resultatet. De to byggene vi har målt er oppbygd på to forskjellige prinsipper. Det ene bygget er av massivtre og har en etasjeskiller med massivtre, og det andre bygget er et modulbygg med et dobbelt lag av etasjeskiller består hovedsakelig av bjelkelag.

Ut fra dette skulle vi inn å måle egenskapene for demping av luftlyd og trinnlyd i begge byggene. Målingene ble foretatt ved bruk av en Norsonic140 måler med tilhørende utstyr. Det ble brukt forsterker, høyttaler og mikrofon for å måle luftlyd, samt en tappingmaskin i tillegg til mikrofonen for å måle trinnlyd.

Målingene våre ga godkjente verdier i henhold til kravet for lydklasse c i teknisk forskning, der vi havnet på en demping av luftlyd på 59dB for massivtre-bygget og 65dB demping for modulbygget. Trinnlydmålingene ga et litt dårligere resultat, men det var fremdeles akkurat innenfor kravet. Bygget av massivtre slapp igjennom 53dB trinnlyd og modulbygget slapp igjennom 52dB trinnlyd.

Kravet i teknisk forskrift er minimum 55dB demping av luftlyd og en maksimal gjennomgang på 53dB for trinnlyd.
 
In this project, we measured and tested two different buildings with student housing in order to assess the acoustic properties of the constructions against the requirements set by the technical regulations. We conducted measurements vertically across the floor/ceiling assemblies to evaluate the amount of sound transmitted between floors. The requirement set for the project was to focus on floor assemblies, specifically those made of wood-based materials.

The purpose of the project was to learn how to use acoustic measurement instruments, as well as to assess how the student housing buildings in the area perform in relation to the acoustic requirements specified in the technical regulations. One of the buildings we measured had previously received several complaints from residents about noise, making it an especially interesting subject for testing.

The two buildings we measured are constructed using two different principles. One building is made of cross-laminated timber (CLT) with a CLT floor assembly, while the other is a modular building with a traditional joist floor assembly. Based on this, we conducted measurements of airborne sound insulation and impact sound insulation in both buildings. The measurements were performed using a Norsonic 140 sound level meter with accompanying equipment. An amplifier, loudspeaker, and microphone were used to measure airborne sound, and a tapping machine along with a microphone was used to measure impact sound.

Our measurements produced values that met the requirements for sound class C according to the technical regulations. The airborne sound insulation was measured at 59 dB for the CLT building and 65 dB for the modular building. The impact sound insulation results were slightly worse, but still just within the required limits. The CLT building transmitted 53 dB of impact sound, while the modular building transmitted 52 dB.

The technical regulation requires a minimum airborne sound insulation of 55 dB and a maximum impact sound transmission of 53 dB.
 
Publisher
NTNU

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit
 

 

Browse

ArchiveCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsDocument TypesJournalsThis CollectionBy Issue DateAuthorsTitlesSubjectsDocument TypesJournals

My Account

Login

Statistics

View Usage Statistics

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit