Dokumentasjon av ventilasjonsaggregat

Christian Dahl Pedersen
Bachelor thesis
Thumbnail
URI
https://hdl.handle.net/11250/3076364
Date
2023
Metadata
Show full item record
Collections
  • Institutt for energi og prosessteknikk [4541]
Description
Full text not available
Abstract
I denne bacheloroppgaven skal det dokumenteres av et ventilasjonsaggregat i lab i

Varmeteknisk bygg. Det ble bestemt å utføre tilstandskontroll av temperaturmålerne for

aggregatet og måleren for utetemperaturen. Formålet er å verifisere at temperaturmålerne i

anlegget oppholder de riktige verdiene ettersom systemet reguleres etter målerne. Videre

gjennomføres det målinger av den roterende varmegjenvinneren for å finne virkningsgraden

på ulike effekter for frekvensomformeren. Grunnen er å se om frekvensen til

varmegjenvinneren er unødvendig høy og kan genereres på et lavere nivå.

Ventilasjonssystemet er utstyrt med spjeld, filter, varmegjenvinner, tilluftf og avtrekksvifte,

varmebatteri og to kjølemediumer. Systemet styres automatisk eller med manuell bruk av SDprogrammet. Utover aggregatet er det innstilt ulike rekke målekomponenter som trykk,

fuktighet, temperatur, luftmengde som tilviser verdiene sine på spesifikke plasseringer i

systemet. For virkningsgrad er det fire posisjoner som må måles; temperaturen før og etter

den roterende varmegjenvinneren på tilluft- og avtrekksiden.

Den valgte fremgangsmåten var å bruke andre måleinstrumenter der de ble plassert i samme

posisjoner som de andre temperaturmålerne. Deretter ble ønsket romtemperatur økt til 30

grader, og begge måleinstrumentene ble målt i samme tidspunkter. For utetemperaturen ble

tatt tre forskjellige målinger for å se om solstrålingen hadde effekt på utetemperaturmåleren.

SD-programmet ble brukt for å justere eller notere måleverdiene. Målingene ble til slutt

plottet inn og illustrert gjennom tabeller eller diagrammer.

Da målingene var gjort og analysert, kom det klart frem at utetemperaturmåleren var påvirket

av solstrålingen med 12 grader i forskjell fra luften i inntaksristen. For virkningsgraden ville

den holde seg stabilt etter 75 % for frekvensomformeren med en økning på 1.2% .

For temperaturmålerne i aggregatet viser det seg å være i akseptable målegrenser og trenger

ingen justering. For utetemperaturmåleren derimot, anbefales det at utetemperaturmåleren blir

plassert i en annen posisjon som veggen bak eller i skyggen, der det ikke blir påvirket av

solstråling. For den roterende varmegjenvinneren kan den redusere sin frekvensomformer til

75 % og opprettholde god varmegjenvinning og luftkvalitet.
 
In this bachelor's thesis, it will be made a documentation on a ventilation unit in a lab in the

Varmeteknisk building. It was decided to carry out a condition check of the temperature

gauges for the unit and the gauge for the outdoor temperature. The purpose is to verify that

the temperature measurents in the facility maintain the correct values as the system is

regulated according to the gauges. Furthermore, measurements are carried out of the rotating

heat recovery unit to find the efficiency of various effects for the frequency converter. The

reason is to see if the frequency of the heat recovery is unnecessarily high and can be

generated at a lower level.

The ventilation system is equipped with a damper, filter, heat recovery unit, supply air and

exhaust fan, heating coil and two cooling media. The system is controlled automatically or

with manual use of the SD program. In addition to the aggregate, various measuring

components such as pressure, humidity, temperature, air volume are set which display their

values at specific locations in the system. For efficiency there are four positions that must be

measured; the temperature before and after the rotating heat recovery unit on the supply air

and exhaust side.

The method chosen was to use other measuring instruments where they were placed in the

same positions as the other temperature gauges. The desired room temperature was then

increased to 30 degrees, and both measuring instruments were measured at the same times.

For the outdoor temperature, three different measurements were taken to see if the solar

radiation had an effect on the outdoor temperature gauge. The SD program was used to adjust

or record the measurement values. The measurements were finally plotted and illustrated

through tables or diagrams.

When the measurements had been made and analyzed, it became clear that the outside

temperature measurement was affected by the solar radiation by 12 degrees in difference from

the air in the intake grille. For the efficiency, it would remain stable after 75% for the

frequency converter with an increase of 1.2%.

For the temperature gauges in the aggregate, it turns out to be within acceptable measurement

limits and does not need any adjustment. For the outdoor temperature gauge, on the other

hand, it is recommended that the outdoor temperature gauge be placed in a different position

such as the wall behind or in the shade, where it is not affected by solar radiation. For the

rotary heat recovery, it can reduce its frequency converter to 75% and maintain good heat

recovery and air quality.
 
Publisher
NTNU

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit
 

 

Browse

ArchiveCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsDocument TypesJournalsThis CollectionBy Issue DateAuthorsTitlesSubjectsDocument TypesJournals

My Account

Login

Statistics

View Usage Statistics

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit